Transfer walls shall comply with 1009.4....
Search Results "Transfer Support"
Commonly Searched Documents
-
Transfer Walls: ADA Standard Section 1009.4
-
a. Structural Strength
The MDE NPRM proposed to require transfer supports to be capable of resisting vertical and horizontal forces of 250 pounds at all points (proposed M305.2.2)....
-
M301.3 Transfer Supports
M301.3 Transfer Supports Proposed requirement: Transfer supports shall be provided for use with the transfer sides required by M301.2.3 and shall comply with M305.2....
-
Transfer Platforms: ADA Standard Section 1008.3.1
Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with 1008.3.1....
-
M302.3.1 Transfer Supports (Section-by-Section Analysis)
transfer supports must comply with the technical requirements in M305.2 of the proposed rule....
-
Transfer Type Shower Compartments: ADA Standard Section 608.3.1
Section 608.3.1 covers the current ADA Standards for grab bars in transfer type shower compartments.
-
Effect of Handhelds on Transfer Height
Only a few people used the backrests during the transfers....
-
Transfer Steps: ADA Standard Section 1008.3.2
Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required to be on accessible routes....
-
RECOMMENDED CHANGE
RECOMMENDED CHANGE Revise the Section 5.4.11 recommendation as follows: The Committee recommends transfer supports and connections contain the strength to resist vertical forces of...
-
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces....
-
Grab Bar and Backrest Evaluation
The grab bars were frequently used as handhelds during the transfer process and for one person it made the difference of being able to do a non-level transfer to the platform....
-
11B-407.4.10 Support rail
Support rails shall be provided on at least one wall of the car. Advisory 11B-407.4.10 Support rail....
-
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces On imaging equipment with transfer surfaces, the transfer surface is oriented...
-
Wheelchair Spaces, Ride Seats Designed for Transfer, and Transfer Devices: ADA Standard Section 206.2.9.2
Section 206.2.9.2 covers the ADA Standards for accessible routes to wheelchair spaces, ride seats designed for transfer and transfer devices in amusement rides.
-
Transfer Steps: ADA Standard Section 1009.5.4
Transfer step height shall be 8 inches (205 mm) maximum....
-
Transfer Entry: ADA Standard Section 1002.5.3
Where openings are provided for transfer to amusement ride seats, the openings shall provide clearance for transfer from a wheelchair or mobility aid to the amusement ride seat....
-
M302.3 Supports
Transfer supports, leg supports and reclining surfaces shall comply with M302.3....
-
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment....
-
M302.3 Supports
Transfer supports, armrests, and reclining surfaces shall comply with M302.3....
-
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface where...
-
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers....
-
5.4.2.1 Transfer Support Length for Stretchers
5.4.2.1 Transfer Support Length for Stretchers. Transfer supports on stretchers should be a minimum of 15 inches long....
-
M305.2 Transfer Supports
M305.2 Transfer Supports M305.2.2 Transfer Supports Structural Strength Proposed requirement: Transfer supports and their connections shall be capable of resisting vertical and...
-
5.4.1.2 Transfer and Positioning Support Location Recommendations for Imaging Equipment with Transfer Surfaces
transfer supports on tables with transfer depths of less than or equal to 24 inches and positioning supports for transfer depths greater than 24 inches....