sides, provided that they did not extend above the top of the transfer surface....
Search Results "Side Transfer Surface"
Commonly Searched Documents
-
d. Unobstructed Transfer
-
5.2.1.3 Transfer Surface Size for Stretchers
5.2.1.3 Transfer Surface Size for Stretchers. The transfer surface should be 28 inches wide minimum and 17 inches deep minimum located on both long sides of stretchers....
-
4.3.5 Transfer Height
Tent platform surfaces that are not the same elevation as the ORAR shall be between 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor or ground surface adjacent to...
-
Transfer Supports: ADA Standard Section 1008.3.2.3
At least one means of support for transferring shall be provided. Advisory 1008.3.2.3 Transfer Supports....
-
Side Entry: ADA Standard Section 1002.4.4.2
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
-
Transfer Systems: ADA Standard Section 1009.5
Transfer systems shall comply with 1009.5....
-
Transfer Walls: ADA Standard Section 1009.4
Transfer walls shall comply with 1009.4....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
5.4.2.1 Transfer Support Length Recommendation for Stretchers
5.4.2.1 Transfer Support Length Recommendation for Stretchers On Stretchers, the transfer surface is oriented along the long dimension of the surface on which patients are positioned...
-
Transfer Supports: ADA Standard Section 1008.3.1.4
At least one means of support for transferring shall be provided. ...
-
4.1.2 Surface Design of Examination Tables and Chairs
This contouring complicates efforts to measure the distance between the floor and the height of the surface onto which patients transfer for their examinations....
-
Transfer Platforms: ADA Standard Section 1008.3.1
Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with 1008.3.1....
-
5.2.1.3 Transfer Surface Size Recommendations for Stretchers (M301)
5.2.1.3 Transfer Surface Size Recommendations for Stretchers (M301) The Committee recommends a minimum transfer surface size of 28 inches wide by 17 inches deep for stretchers located...
-
Transfer Surface Height (M301.2.1 and M302.2.1)
from the floor may vary across the transfer surface....
-
5.3 Transfer Sides
5.3 Transfer Sides....
-
M301.2 Transfer Surface (Section-by-Section Analysis)
This is an introductory section.
-
Transfer Steps: ADA Standard Section 1009.5.4
Transfer step height shall be 8 inches (205 mm) maximum....
-
5.3.2 Transfer Sides for Equipment Used by Patients in a Supine, Prone, or Side-Lying Position
5.3.2 Transfer Sides for Equipment Used by Patients in a Supine, Prone, or Side-Lying Position....
-
Transfer Surface Size: Equipment Used by Patients in Supine, Prone, or Side-Lying Position (M301.2.2)
On diagnostic equipment used by patients in a supine, prone, or side-lying position, M301.2.2 would require the size of the transfer surface (i.e., part of the diagnostic equipment onto...
-
Transfer Type Shower Compartments: ADA Standard Section 608.3.1
Section 608.3.1 covers the current ADA Standards for grab bars in transfer type shower compartments.
-
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position....
-
Transfer Steps: ADA Standard Section 1008.3.2
Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required to be on accessible routes....
-
Transfer Heights
Transfers to level surfaces require less exertion on the upper extremities [5, 10, 11]. Transfers are easiest and safest to obtain when they are as close to level as possible [6]....
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.