Protruding objects shall comply with 307....
Search Results "Protruding Object"
-
307.1 General
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
307.3 Post-Mounted Objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above...
-
307.5 Required Clear Width
Protruding objects shall not reduce the clear width required for accessible routes....
-
R210 Protruding Objects
R210 Protruding Objects....
-
Attachment A: Violations Identified in the United States' Letter of Findings (Sept. 29, 2014)
-
Vertical clearance and protruding objects
• Entrances and aisles with adequate head clearance and minimal projections into the path of travel result in easier navigation for people with lessened visual acuity or those who...
-
307 Protruding Objects
Objects mounted on walls and posts can be hazardous to persons with vision impairments unless treated according to the specifications in section 307 for protruding objects....
-
H14
H14. Are all built-in dispensers, receptacles, or equipment mounted so the front does not extend more than 4 inches from the wall if the bottom edge is between 27 inches and 80...
-
Protruding objects and vitrines
Protruding objects and vitrines: e....
-
F204 Protruding Objects
-
Protruding Objects
This guide explains requirements in the ADA Standards for protruding objects....
-
F204.1 General
Protruding objects on circulation paths shall comply with 307. EXCEPTIONS: 1....
-
Protruding Objects [§204]
Protruding Objects [§204] To prevent hazards to people with vision impairments, the standards limit the projection of objects into circulation paths....
-
Protrusion Limits [§307.2]
Objects mounted on walls, partitions, columns, and other elements along circulation paths can pose hazards unless their projection is limited....
-
Location Above Detectable Elements
Objects located above elements that are within can sweep can protrude 4” maximum from the leading edge of such elements provided that any required reach or clear floor space is not obstructed...
-
Side Partitions and Wing Walls
Side partitions or panels and wing walls can also be used to make protruding objects compliant. The bottom edge of panels or partitions must be 27” high maximum....
-
Recessed Objects
Objects can be recessed in alcoves so that they do not project more than 4” into circulation paths....
-
Post-Mounted Objects [§307.3]
Post-Mounted Objects [§307.3] Free-standing objects with leading edges 27” to 80” high that are mounted on posts or pylons cannot protrude more than 12” into circulation paths....
-
Common Questions (Protruding Objects)
Common Questions
-
Are requirements for protruding objects limited to hallways and corridors?
No, requirements for protruding objects apply to all circulation paths, including those in rooms and spaces off corridors. They apply to both interior and exterior circulation paths....
-
Do drinking fountains pose hazards as protruding objects?
Cantilevered units at standard heights for people who stand must be recessed or protected as protruding objects....
-
Protruding Objects [1017.9]
Objects that protrude into the trail clear tread width, passing spaces, and resting intervals can pose hazards to people who are blind or have low vision....
-
J6
J6. Is the bottom of the apron of the fountain 27 inches above the floor so that it provides the space needed for a person who uses a wheelchair to pull up under it but is not a...