Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
Search Results "Maximum Reach Depth"
-
308.3.1 Unobstructed
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
11B-308.3.2 Obstructed high reach
and the depth of the obstruction shall be 24 inches (610 mm) maximum....
-
11B-308.3.2 Obstructed high reach
and the depth of the obstruction shall be 24 inches (610 mm) maximum....
-
11B-308.3.2 Obstructed high reach
and the depth of the obstruction shall be 24 inches (610 mm) maximum....
-
Side Reach [4.2.6]
High and low reaches are based on a depth of reach no greater than 10 inches measured from the available clear floor space....
-
Reach Ranges and Operability Requirements
Obstructed Forward Reach—When an object must be reached over an obstruction, the clear floor space must extend beneath the obstruction for at least as far as the reach depth over the obstruction...
-
4.25.3 Height
Accessible storage spaces shall be within at least one of the reach ranges specified in 4.2.5 and 4.2.6 (see Fig. 5 and Fig 6)....
-
308 Reach Ranges
Accessible reach ranges are specified according to the approach (forward or side) and the depth of reach over any obstruction....
-
4.3 Reach Ranges
Upper Side Reach Figure 19....
-
Side reach (Section-by-Section Analysis)
Side reach. The 1991 Standards at section 4.2.6 establish a maximum side-reach height of 54 inches. The 2010 Standards at section 308.3.1 reduce that maximum height to 48 inches....
-
Side reach (Section-by-Section Analysis)
Side reach. The 1991 Standards at section 4.2.6 establish a maximum side-reach height of 54 inches. The 2010 Standards at section 308.3 reduce that maximum height to 48 inches....
- Figure 308.3.2 Obstructed High Side Reach – Drawing from the U.S. Access Board
-
A4.2.5 & A4.2.6 Reach
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a)....
-
A4.2.5 & A4.2.6 REACH
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a)....
-
Side Approach
Side Approach The maximum reach depth for a high (54 inch maximum) reach is 10 inches, measured from the clear floor space....
-
Submerged Depth: ADA Standard Section 1009.3.2
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
Side Approach
Side Approach Where space is provided for a side approach, controls can be mounted at the heights allowed for side reaches....
-
Forward Reach: ADA Standard Section 308.2
Section 308.2 covers the current ADA Standards for forward reach.
-
Reach Ranges: ADA Standard Section 308
Section 308 covers the current ADA Standards for reach ranges.
-
Submerged Depth: ADA Standard Section 1009.2.8
The lift shall be designed so that the seat will submerge to a water depth of 18 inches (455 mm) minimum below the stationary water level....
-
Side Approach
Side Approach Side reach depth is important to consider in the design and location of sinks....
-
Knee and Toe Space
If the forward reach to operable parts extends over an obstruction, such as a counter, clearances for toes and knees is required below....