medical diagnostic equipment (MDE Standards) contain minimum technical criteria to ensure that medical diagnostic equipment, including but not limited to, examination tables, examination chairs...
Search Results "Mammography Chair"
-
36 CFR Part 1195 Standards for Accessible Medical Diagnostic Equipment - Preamble
- Outdoor Extreme Mobility Beach Cruiser Powered Wheelchair
-
b. Exception for Base Support Allowance and Unobstructed Knee and Toe Space
This commenter recommended revisions to allow for a base lip on mammography equipment....
- Stryker Stair-PRO 6252
-
4. Breast Platform Adjustability
Additionally, the Access Board proposed specific technical requirements for breast platforms of mammography equipment....
-
36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment - Example Applications of Proposed Standards
Example Applications of the Proposed Medical Diagnostic Equipment Accessibility Standards January 23, 2012
-
Boston Center for Independent Living, Inc.
Re: Comments on Exam Tables and Chairs Subcommittee Report Dear Mr. Pace, Ms. Sesker, and Members of the U.S....
-
M303.4.1 Breast Platform Adjustability
Breast platforms shall be continuously adjustable from a low height of 26 inches (660 mm) to a high height of 42 inches (1065 mm) above the floor.
-
M303.4.1 Breast Platforms
The height of the breast platform shall be 30 inches (760 mm) high minimum and 42 inches (1065 mm) high maximum above the floor when in use by a patient seated in a wheelchair.
-
36 CFR Part 1195 Standards for Accessible Medical Diagnostic Equipment
medical diagnostic equipment (MDE Standards) contain minimum technical criteria to ensure that medical diagnostic equipment, including but not limited to, examination tables, examination chairs...
-
Permanently Installed Systems
In some, the individual transfers from a wheelchair to the portable controlled descent chair....
-
Transfer Surface Size – M302.2.2 Seated Position
In addition, examination chairs that cannot be entered on the foot end, such as dental chairs and podiatry chairs, the subcommittee members agreed that the 17 inch minimum depth and 21 inch...
- RESNA Position Paper on the Use of Evacuation Chairs
-
The Brewer Company, LLC
We request the Access Board to consider the following points in favor of the 19” low height: 1) The Subcommittee on Tables and Chairs convened by the U.S....
-
National Network of ADA Centers
The minimum low and high height for compliance are stated and still allow for higher heights for motorized chairs, scooters, and people who ambulate using walkers, crutches or other type...
-
Base Support [No specific provision—affects M303.2.4]
users and over 95% of power chair users....
-
5.2.2.1 Transfer Surface Width Recommendations for M302
5.2.2.1 Transfer Surface Width Recommendations for M302 The Committee recommends 21 inches for the minimum width of the transfer surface of examination chairs and other equipment primarily...
-
National Council on Independent Living
The study showed that increasing the low end to 19 inch height excludes many users, specifically over 30% of female manual chair users and over 15% of male manual chair users....
-
Motor Impairments
Motor Impairments: To evacuate individuals with motor impairments, employers can purchase evacuation devices. These devices help move people with motor impairments down the...
- Living Earth Crafts Cloud 9 Cuvee Spa Treatment Table
- Living Earth Crafts Cloud 9 Spa Treatment Table
-
5.2.2.1 Transfer Surface Width
The transfer surface should be 21 inches wide minimum for examination chairs and other equipment used by patients in a seated position....