At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
Search Results "Grab Bar Location"
Commonly Searched Documents
-
11B-1009.4.5 Grab bars
- Mayer-Rothschild Foundation: Determination of Grab Bar Specifications for Independent and Assisted Transfers in Residential Care Settings
-
11B-604.5.2 Rear wall
Where an administrative authority requires flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall...
-
11B-604.5 Grab bars
[2010 ADA Standards] 604.5 Grab Bars. Grab bars for water closets shall comply with 609....
-
General: ADA Standard Section 609.1
Section 609.1 of the ADA Standards covers information in the current ADA Standards for grab bars in toilet facilities and bathing facilities.
-
609.4 Position of Grab Bars
609.4 Position of Grab Bars....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
Cross Section: ADA Standard Section 609.2
Section 609.2 covers the current ADA Standards for grab bar cross sections.
-
11B-609.4 Position of grab bars
11B-609.4 Position of grab bars....
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
4.17.6 Grab Bars
Grab bars complying with the length and positioning shown in Fig. 30(a), (b), (c), and (d) shall be provided....
-
4.17.6 GRAB BARS
Grab bars complying with the length and positioning shown in Fig. 30(a), (b), (c), and (d) shall be provided....
-
11B-609 Grab bars
[See subsections ...]
-
Positioning
According to ADAAG, positioning is dependent on two factors, height and location of grab bars, both of which were altered by designers to better accommodate an older population....
-
11B-609.1 General
Grab bars in toilet facilities and bathing facilities shall comply with Section 11B-609....
-
Circular Cross Section: ADA Standard Section 609.2.1
Section 609.2.1 covers the current ADA Standards for circular grab bar cross sections.
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. ...
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. ...
-
11B-604.8.2.3 Grab bars
Grab bars shall comply with Section 11B-609. A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....
-
11B-609.6 Fittings
Grab bars shall not rotate within their fittings....