Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. Figure 409.4.6.2 Location of Private Residence Elevator Control Panel...
Search Results "Elevator Car Control"
-
409.4.6.2 Location
-
4.10.12* CAR CONTROLS
Elevator control panels shall have the following features:...
-
4.10.12* Car Controls
Elevator control panels shall have the following features:...
-
4.10.12(1)
All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They shall be raised or flush....
-
4.10.12(1)
All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They may be raised or flush....
-
4.10.12(2)
(2) Tactile, Braille, and Visual Control Indicators....
-
4.10.12(2)
(2) Tactile and Visual Control Indicators....
-
4.10.12(3)
Emergency controls, including the emergency alarm and emergency stop, shall be grouped at the bottom of the panel and shall have their centerlines no less than 35 in (890 mm) above the floor...
-
4.10.12(3)
Emergency controls, including the emergency alarm and emergency stop, shall be grouped at the bottom of the panel and shall have their centerlines no less than 35 in (890 mm) above the finish...
-
4.10.12(4)
Controls shall be located on a front wall if cars have center opening doors, and at the side wall or at the front wall next to the door if cars have side opening doors (see Fig. 23(c) and...
-
4.10.12(4)
Controls shall be located on a front wall if cars have center opening doors, and at the side wall or at the front wall next to the door if cars have side opening doors (see Fig. 23(c) and...
-
Car Controls [4.10.12]
Alignment for a side reach is often difficult at panels on the front of cars due to the limited maneuvering space; consider a maximum height of 48 inches for panels on the front of cars....
-
Elevators
Elevators....
-
407.4.6 Elevator Car Controls
Where provided, elevator car controls shall comply with 407.4.6 and 309.4....
-
407.4.6.1 Location
Controls shall be located within one of the reach ranges specified in 308. EXCEPTIONS: 1....
-
407.4.6.2 Buttons
Car control buttons with floor designations shall comply with 407.4.6.2 and shall be raised or flush. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
407.4.6.2.1 Size
Buttons shall be ¾ inch (19 mm) minimum in their smallest dimension.
-
407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor....
-
407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel....
-
407.4.7 Designations and Indicators of Car Controls
Designations and indicators of car controls shall comply with 407.4.7....
-
407.4.7.1 Buttons
Car control buttons shall comply with 407.4.7.1....
-
407.4.7.1.1 Type
Control buttons shall be identified by tactile characters complying with 703.2....
-
407.4.7.1.2 Location
Raised character and braille designations shall be placed immediately to the left of the control button to which the designations apply....