The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors....
Search Results "Continuous Width"
Commonly Searched Documents
-
11B-809.7.1 Width
-
403.5.1 Clear Width
403.5.1 Clear Width. Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches (915 mm) minimum....
-
403.5.1 Clear Width
Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches (915 mm) minimum....
-
403.5.1 Clear Width
Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches (915 mm) minimum....
-
Clear Width [4.8.3]
The minimum dear width for ramps of 36 inches is measured between the leading edge of handrails. A maximum clear width is not specified....
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1....
-
Width [4.3.3.] and Passing Space [4.3.4]
A continuous minimum clear width of 36 inches is required for accessible routes, but a reduction to 32 inches is allowed for a linear distance of no more than 24 inches (e.g., a doorway)...
-
7.4.12.1 Clear Width
Gate openings and openings in barriers for hiker passage shall provide a clear width of 36 inches (915 mm), complying with ODAAG, section 1017.3 Clear Tread Width....
-
11B-403.5.1 Clear width
Exceptions: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum for a length of 24 inches (610 mm) maximum provided that reduced width segments are separated...
- Figure 403.5.2 Clear Width at Turn – Drawing from the U.S. Access Board
-
4.8.3 Clear Width
The minimum clear width of a ramp shall be 36 in (915 mm)....
-
4.8.3 CLEAR WIDTH
The minimum clear width of a ramp shall be 36 in (915 mm)....
- Figure 604.7 Dispenser Outlet Location – Drawing from the U.S. Access Board
-
R304.5.1 Width
The SNPRM would revise R304.5.1 to read as follows: R304.5.1 Width. The width of curb ramps and blended transitions shall comply with 304.5.1.1 or 304.5.1.2, as applicable....
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 90-degree Turn
The bold dashed line in the table and figure indicates the current ADA-ABA requirement of a 91.5 cm (36 in.) passage width....
-
4.7.3 Width
The minimum width of a curb ramp shall be 36 in (915 mm), exclusive of flared sides....
-
4.7.3 WIDTH
The minimum width of a curb ramp shall be 36 in (915 mm), exclusive of flared sides....
-
2.10.1 Clear Width
Gate openings and openings in barriers for pedestrian passage shall provide a clear width of 36 inches (915 mm), complying with ODAAG, section 1017.3 Clear Tread Width....
-
6.14.1 Clear Width
Gate openings and openings in barriers for pedestrian passage shall provide a clear width of 36 inches (915 mm), complying with ODAAG, section 1017.3 Clear Tread Width....
-
Width: ADA Standard Section 407.3.6
Section 407.3.6 covers the current ADA Standards for elevator door width.
-
403.5.2 Clear Width at Turn
403.5.2 Clear Width at Turn....
-
R407.6.2 Width
R407.6.2 Width. The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
403.5.2 Clear Width at Turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1220 mm) wide, clear width shall be 42 inches (1065 mm) minimum approaching the turn, 48...
-
F. Clear Width
Do all entry doors to accessible guestrooms and other interior doors (except doors on shallow closets) allow at least 32" of clear passage width to accommodate persons who use wheelchairs...