Section 37.51 Key Stations in Commuter Rail Systems These sections require that key stations in light, rapid, and commuter rail systems be made accessible as soon as practicable, but...
Search Results "Commuter Rail Car"
Commonly Searched Documents
-
Section 37.51 Key Stations in Commuter Rail Systems
-
§ 38.101(a)
(a) Any stepwell or doorway with a lift, ramp or bridge plate shall have, when the door is open, at least 2 footcandles of illumination measured on the step tread, ramp, bridge...
-
§ 38.107 Restrooms
[See subsections ...]
-
§ 38.101 Lighting
[See subsections ...]
-
§ 38.97 Interior circulation, handrails and stanchions
[See subsections ...]
-
§ 38.95(a)(1) General
All new commuter rail cars, other than level entry cars, covered by this subpart shall provide a level-change mechanism or boarding device (e.g., lift, ramp or bridge plate) complying with...
-
New and Altered Fixed Guideway Stations: ADA Standard Section 218.2
Section 218.2 covers scoping requirements in the current ADA Standards for new and altered fixed guideway stations.
-
11B-218.2 New and altered fixed guideway stations
New and altered stations in rapid rail, light rail, commuter rail, intercity rail, high speed rail, and other fixed guideway systems shall comply with Sections 11B-810.5 through 11B-810.10...
-
§ 38.93(a)(1)
(1) At least one door on each side of the car from which passengers board opening onto station platforms and at least one adjacent doorway into the passenger coach compartment, if provided...
-
§ 38.103(a)
(a) Each car shall be equipped with an interior public address system permitting transportation system personnel, or recorded or digitized human speech messages, to announce stations and...
-
§ 38.95(b)(7) Platform gaps
When the lift is at car floor height with the inner barrier down (if applicable) or retracted, gaps between the forward lift platform edge and car floor shall not exceed 1/2 inch horizontally...
-
§ 38.95(c)(6) Attachment
(6) Attachment—.
-
§ 38.95(b)(12) Use by standees
(12) Use by standees. Lifts shall accommodate persons using walkers, crutches, canes or braces or who otherwise have difficulty using steps. The lift may be marked to indicate a...
-
§ 38.95(c)(1) Design load
(1) Design load. Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26...
-
§ 38.95(b)(3) Emergency operation
(3) Emergency operation. The lift shall incorporate an emergency method of deploying, lowering to ground or platform level with a lift occupant, and raising and stowing the empty...
-
§ 38.95(c)(7) Stowage
(7) Stowage. A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps or bridge plates, including portable ramps or bridge plates...
-
§ 38.95(b)(1) Design load
(1) Design load. The design load of the lift shall be at least 600 pounds. Working parts, such as cables, pulleys, and shafts, which can be expected to wear, and upon which the lift...
-
§ 38.95(b)(2) Controls
(2) Controls—
-
§ 38.95(b)(11) Boarding direction
(11) Boarding direction. The lift shall permit both inboard and outboard facing of wheelchairs and mobility aids.
-
12162(c) Used rail cars
(c) Used rail cars It shall be considered discrimination for purposes of section 1132 of this title and section 794 of title 29 for a person to purchase or lease a used rail passenger...
-
14. In § 38.93(d)(3)
§ 38.93 [Amended] 14. In § 38.93(d)(3), remove the period at the end of the paragraph and add the following words: “,ensuring compliance with section 37.42, where applicable.” in...
-
§ 38.97(b)
(b) Where provided, handrails or stanchions shall be sufficient to permit safe boarding, on-board circulation, seating and standing assistance, and alighting by persons with...
-
§ 38.93(a) Clear width
(a) Clear width.
-
§ 38.99(b)
(b) All thresholds and step edges shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor,...