points) to ensure correct accessible slopes (5% running slope and 2.08% cross slope). 11B-403 Verify forms for sidewalks, ramps, landings, curb ramps and clear...
Search Results "Clear Floor Space"
-
Rough Form and Foundation Inspection
-
Rough Form and Foundation Inspection
points) to ensure correct accessible slopes (5% running slope and 2.08% cross slope). 11B-403 Verify forms for sidewalks, ramps, landings, curb ramps and clear...
-
2. a. iii. Clear (Path-of-Travel) Floor Space
Access also includes how people will move into and around lobby and office reception areas, and determine the unobstructed floor or ground space to accommodate a wheelchair user....
-
2. a. iv. Path-of-Travel (wheelchair) space allowances
Path-of-Travel (wheelchair) space allowances.xii In general, a 36” wide accessible route is needed with a slightly larger space provided at corners....
-
§27.71(k)
(k) Shared-use automated airport kiosks provided in accordance with paragraph (j) of this section must conform to the following technical accessibility standards with respect to...
-
§27.71(k)(2) Clear floor or ground space.
(2) Clear floor or ground space. A clear floor or ground space complying with section 305 of the U.S....
-
305 Clear Floor or Ground Space for Wheelchairs
-
305.1 General
Clear floor or ground space shall comply with 305....
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum....
-
305.4 Knee and Toe Clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306....
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm)wide minimum where the depth exceeds 24 inches (610 mm).
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm).
-
2.4 Patient Areas
Is there space in the waiting room for wheelchair users to sit?...
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
§ 38.83(a)(1) General
plate) complying with either paragraph (b) or (c) of this section and sufficient clearances to permit at least two wheelchair or mobility aid users to reach areas, each with a minimum clear...
-
Voting Areas
There also must be enough clear floor space in at least one voting station or booth to allow a voter using a wheelchair or other mobility device to approach, maneuver, and leave the voting...
-
§ 38.107(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches....
-
Appropriate clear floor space
Appropriate clear floor space (shown by dashed lines) is needed adjacent to each cell feature (see page 1 diagrams on clear floor space)....
-
309.2 Clear Floor Space
A clear floor or ground space complying with 305 shall be provided. ...