The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
Search Results "Bitmap Image"
Commonly Searched Documents
-
M301.4.2 Clearance Around Base
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
The MDE NPRM proposed certain clearance requirements beneath the diagnostic equipment to allow sufficient space for the legs of a portable patient lift to fit underneath the...
-
M301.4.2 Clearance Around Base (Section-by-Section Analysis)
The MDE NPRM proposed certain requirements to provide clearance around the base of the diagnostic equipment to allow the legs of the portable floor lift to straddle the base of the...
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.2 Clearance Around Base
[See subsections ...]
-
11B-202 Existing buildings and facilities
Imaging Equipment) - Permanently secured imaging equipment is considered part of the architecture of the building; therefore, projects consisting solely of the replacement of imaging equipment...
-
M305.2.3 Height
EXCEPTION: Where the width of the transfer surface for imaging beds exceed 24 inches (610 mm), the tops of the gripping surfaces shall be permitted to be 3 inches (75 mm) minimum and 6 inches...
-
36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment - Example Applications of Proposed Standards
Example Applications of the Proposed Medical Diagnostic Equipment Accessibility Standards January 23, 2012
-
EXHIBIT 1 JEFFERSON OUTPATIENT IMAGING ADA POLICY AND PROCEDURE
In accordance with Title III of the Americans with Disabilities Act (ADA), Jefferson Outpatient Imaging and Radiology (“Jefferson Outpatient”) does not discriminate on the basis of disability...
-
36 CFR Part 1195 Standards for Accessible Medical Diagnostic Equipment - Preamble
minimum technical criteria to ensure that medical diagnostic equipment, including but not limited to, examination tables, examination chairs, weight scales, mammography equipment, and other imaging...
-
M305.4 Leg Supports
Leg supports shall provide a method of supporting, positioning, and securing the patient’s legs.
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
M301.1 General
Diagnostic equipment that supports patients in a supine, prone, or side-lying position shall comply with M301. EXCEPTION: Examination chairs complying with M302 that recline to...
-
M301.2.3 Size
The size of the transfer surface shall comply with M301.2.3.1 or M301.2.3.2. The size of transfer surfaces shall be measured from center points of their opposing sides.
-
M301.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used in the supine, prone, or side-lying position of 30 inches wide and 15 inches deep minimum. (proposed...
-
5.2.1.1 Transfer Surface Width
5.2.1.1 Transfer Surface Width. The transfer surface should be 28 inches wide minimum for equipment used by patients in a supine, side-lying, or prone position.
-
5.2 Transfer Surface Size for Equipment Used by Patients in Supine, Prone, or Side-Lying Position
5.2 Transfer Surface Size for Equipment Used by Patients in Supine, Prone, or Side-Lying Position.
-
5.2.1 Transfer Surface Size
5.2.1 Transfer Surface Size
-
5.2.1.1 Transfer Surface Width Recommendations for M301
5.2.1.1 Transfer Surface Width Recommendations for M301 The Committee recommends a transfer surface of 28 inches minimum width for equipment used by patients in a supine,...
-
5.2 Transfer Surface Size Recommendations
5.2 Transfer Surface Size Recommendations
-
M301.4.1 Clearance in Base
[See subsections ...]
-
M301.2.2 Size
The transfer surface shall be 30 inches (760 mm) wide minimum and 15 inches (381mm) deep minimum. Advisory M301.2.2 Size. The size requirements in this section apply only to the...
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
M301.1 General
Where diagnostic equipment is used by patients in a supine, prone, or side-lying position, it shall comply with M301.