Exterior area for assisted rescue complying with Section 1007.7....
Search Results "Area of Rescue Assistance"
-
1007.2, Item 10
-
1009.2, Item 10
Exterior areas for assisted rescue complying with Section 1009.7 serving exits at the level of exit discharge....
-
4.3.10* Egress
Accessible routes serving any accessible space or element shall also serve as a means of egress for emergencies or connect to an accessible area of rescue assistance....
-
Egress Stairs
The requirement for a minimum 48 inch width between handrails is specific to stairs adjacent to areas of rescue assistance and does not apply generally to stairs covered by 4.9....
-
4.3.11.4* Two-way Communication
A method of two-way communication, with both visible and audible signals, shall be provided between each area of rescue assistance and the primary entry....
-
4.3.11.5 Identification
Each area of rescue assistance shall be identified by a sign which states “AREA OF RESCUE ASSISTANCE” and displays the international symbol of accessibility....
-
4.3.11.1(4)
(4) A vestibule located immediately adjacent to an exit enclosure and constructed to the same fire-resistive standards as required for corridors and openings.
-
4.3.11.1(5)
(5) A portion of a stairway landing within an exit enclosure which is vented to the exterior and is separated from the interior of the building with not less than one-hour...
-
1007.7.1 Level of exit discharge
Where the exit discharge does not include an accessible route from an exit located on a level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on...
-
4.3.11.1(6)
Smoke barriers shall have a fire-resistive rating of not less than one hour and shall completely enclose the area or room....
-
General
The 1991 Standards require areas of rescue assistance or horizontal exits in facilities with levels above or below the level of exit discharge....
-
1007.11 Instructions
In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted....
-
1003.2.13.7.3 Identification
Exterior areas for assisted rescue shall comply with Section 1003.2.13.5.5....
-
1009.11 Instructions
In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted....
-
1009.11 Instructions
In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted....
-
4.3.11.1(7)
(7) An elevator lobby when elevator shafts and adjacent lobbies are pressurized as required for smokeproof enclosures by local regulations and when complying with requirements herein...
-
4.3.10* EGRESS
Accessible routes serving any accessible space or element shall also serve as a means of egress for emergencies or connect to an accessible place of refuge. Such accessible routes...
-
1007.7.2 Outdoor facilities
Where exit access from the area serving outdoor facilities is essentially open to the outside, an exterior area of assisted rescue is permitted as an alternative to an area of refuge....
-
1009.9 Signage
sign stating: AREA OF REFUGE....
-
1007.9 Signage
Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign stating: AREA OF REFUGE. 2....
-
1009.9 Signage
Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign stating: AREA OF REFUGE. 2....
-
1009.2 Continuity and components
Areas of refuge complying with Section 1009.6. Exterior areas for assisted rescue complying with Section 1009.7 serving exits at the level of exit discharge....
-
1009.2 Continuity and components
Areas of refuge complying with Section 1009.6. Exterior areas for assisted rescue complying with Section 1009.7 serving exits at the level of exit discharge....
-
A4.3.11.3 Stairway Width
A 48 in (1220 mm) wide exit stairway is needed to allow assisted evacuation (e.g., carrying a person in a wheelchair) without encroaching on the exit path for ambulatory persons....