Where the exit discharge does not include an accessible route from an exit located on a level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on...
Search Results "Area of Rescue Assistance"
Commonly Searched Documents
-
1007.7.1 Level of exit discharge
-
4.3.11.1(6)
Smoke barriers shall have a fire-resistive rating of not less than one hour and shall completely enclose the area or room....
-
General
The 1991 Standards require areas of rescue assistance or horizontal exits in facilities with levels above or below the level of exit discharge....
-
1007.11 Instructions
In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted....
-
1003.2.13.7.3 Identification
Exterior areas for assisted rescue shall comply with Section 1003.2.13.5.5....
-
1009.11 Instructions
In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted....
-
1009.11 Instructions
In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted....
-
4.3.11.1(7)
(7) An elevator lobby when elevator shafts and adjacent lobbies are pressurized as required for smokeproof enclosures by local regulations and when complying with requirements herein...
-
4.3.10* EGRESS
Accessible routes serving any accessible space or element shall also serve as a means of egress for emergencies or connect to an accessible place of refuge. Such accessible routes...
-
1007.7.2 Outdoor facilities
Where exit access from the area serving outdoor facilities is essentially open to the outside, an exterior area of assisted rescue is permitted as an alternative to an area of refuge....
-
1009.9 Signage
sign stating: AREA OF REFUGE....
-
1007.9 Signage
Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign stating: AREA OF REFUGE. 2....
-
1009.9 Signage
Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign stating: AREA OF REFUGE. 2....
-
A4.3.11.3 Stairway Width
A 48 in (1220 mm) wide exit stairway is needed to allow assisted evacuation (e.g., carrying a person in a wheelchair) without encroaching on the exit path for ambulatory persons....
-
1009.2 Continuity and components
Areas of refuge complying with Section 1006. Exterior areas for assisted rescue complying with Section 1009.7 serving exits at the level of exit discharge....
-
1007.8.2 Exterior exit stairway
Exterior exit stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
4.1.3(9)*
Areas of rescue assistance shall comply with 4.3.11....
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1220 mm) between handrails....
-
1007.7.6 Stairway
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....
-
Egress [4.1.3(9), 4.3.10]
Otherwise, in new construction, ADAAG requires areas of rescue assistance unless the building is equipped with a supervised automated sprinkler system....
-
4.1.6(1)(g)
(g) In alterations, the requirements of 4.1.3(9), 4.3.10 and 4.3.11 do not apply.
-
1003.2.13.7.2 Exterior exit stairway
Exterior exit stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
Assistive Listening Systems: ADA Standard Section 219
Section 219 covers scoping requirements in the current ADA Standards for assistive listening systems.