What sort of surface is firm and stable? If the answer to both of the following questions is yes, the surface is probably firm and stable....
Search Results "Floor Surface"
-
Step 2: Identify the Presence of Limiting Factors
-
Grab Bars
The top of the gripping surface must be 4 to 6 inches above the wall to provide leverage to the person using the bars....
-
1012.2 Height
Guards shall form a protective barrier not less than 42 inches (1067 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or adjacent seatboard....
-
Protruding Objects [1016.9]
To prevent injuries to people who are blind or have low vision, whenever possible, maintain the vertical clearance free of tree branches a minimum of 80 inches above the ground surface along...
-
1009.4.5 Grab Bars
The top of the gripping surface shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above transfer walls....
-
Signs
Standards) § 4.1.3(16)(a): Raised and Braille letters or numbers (Standards § 4.30.4); Mounting location (§ 4.30.6); Color contrast (§ 4.30.5); and Non-glare surface...
-
4.16.3 Height
Whereas the rationale for seat height in ADAAG is to provide a surface that is at or slightly below the wheelchair seat in order to accommodate a sliding transfer, the rationale in eldercare...
-
Referenced Standards [§105]
elements, including automated doors (ANSI/BHMA standards), means of egress (IBC), fire alarms (NFPA National Fire Alarm Code), elevators and platform lifts (ASME Safety Code), and play surfaces...
-
11B-705.1.2.3 Islands or cut-through medians
cut-through less 2 inches (51 mm) maximum on each side, placed at the edges of the pedestrian island or cut-through median, and shall be separated by 24 inches (610 mm) minimum of walking surface...
-
11B-812.7.2 Marking
The color of the borderlines, hatched lines, and letters shall contrast with that of the surface of the access aisle....
-
3.13(c) Companion Seating
Wheelchair spaces and companion seats shall be located on the same floor level as other seats in the same row — they shall not be higher or lower relative to the other seats in the row or...
-
904.4 Sales and Service Counters
of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with 904.4.1 provided that the required clear floor...
-
5.8.3 Breast Platform Recommendations
The height of the breast platform shall be 30 inches high minimum and 42 inches high maximum above the floor when in use by a patient seated in a wheelchair...
-
H1
ADA Standards § 4.30.6] Yes No If No, install a sign with raised characters and Braille on the wall adjacent to the latch side of the door and centered 60 inches above the floor...
-
K3
table with fixed seats have accessible locations with knee space at least 27 inches high, at least 19 inches deep, and at least 30 inches wide with a table top 28 to 34 inches above the floor...
-
610.2 Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
407.2.2.1 Visible and Audible Signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. EXCEPTIONS: 1....
-
11B-1008.4.3 Play tables
Exception: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-603.5 Accessories
All operable parts, including coin slots, shall be 40 inches (1016 mm) maximum above the finish floor....
-
1008.4.3 Play Tables
EXCEPTION: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...
-
407.12.3.1 Unobstructed Forward Reach (Section-by-Section Analysis)
Analysis) This section proposes that, where an unobstructed forward reach is provided, the operable part must be located 48 inches high maximum and 15 inches high minimum above the floor...
-
407.12.2.2 Obstructed Side Reach (Section-by-Section Analysis)
located more than 10 inches, but not more than 24 inches, behind the vertical reference plane, the height of the operable part must be 46 inches maximum and 15 inches minimum above the floor...