Different 7.3 Check-out Aisles Exception: In alterations, at least one check-out aisle shall be accessible in facilities under 5000 square feet of selling space...
Search Results "Transfer Space"
-
227 Sales and Service
-
ACTIONS TAKEN BY CITY OF WAUKEGAN
During the 2000 fiscal year, they also provided accessible counter space to the counters where city services are provided....
-
Construction Specification Institute
longitudinal lines, measurements were to be taken in minimum 5 - foot lengths running parallel to the long dimension, with one measurement line per 3 feet of width and within 2 feet of edges, spaced...
-
1.1.1
Although ramps with a slope slightly less than 1:12 take up more floor space, the negligible loss in usable space will more than compensate for potential problems caused by rebuilding or...
-
Raised Courtroom Stations Not for Members of the Public
that raised courtroom stations used by judges and other judicial staff do not have to provide full vertical access when first constructed or altered as long as the required clear floor space...
-
11B-610.3 Shower compartment seats
In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry....
-
Ground Level Requirements Based on Elevated Play Components
The intent of this requirement is to provide a variety of experiences for individuals who choose to remain with their mobility devices, or choose not to transfer to elevated play components...
-
ADOPTION OF A 19 INCH HEIGHT MINIMIZES COSTS TO HEALTH CARE PROVIDERS
ADOPTION OF A 19 INCH HEIGHT MINIMIZES COSTS TO HEALTH CARE PROVIDERS In the absence of Committee consensus commending a departure from the existing broadly accepted transfer surface...
-
20. When an employee requests leave as a reasonable accommodation, may an employer provide an accommodation that requires him/her to remain on the job instead?
., reallocation of marginal functions or temporary transfer) as long as it does not interfere with the employee's ability to address his/her medical needs....
-
Walk Through Procedures
This time can be used, for example, to practice evacuation techniques, methods of transferring in and out of evacuation devices, carrying techniques, use of evacuation devices, and use of...
-
11B-610.3 Shower compartment seats
In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry. ...
-
4.2 Stretchers
With these essential features competing for the same vertical space, current stretchers cannot lower to the desired minimum height of 17" to 19" (see Sections 5 and 6)....
-
ASME
This document does not permit the use of inclined stairway chairlifts which do not provide platforms because such lifts require the user to transfer to a seat....
-
3.2 MDE Advisory Committee Process
In all cases except one – the minimum height of transfer surfaces – the Committee reached consensus on the recommended accessibility standards (see Section 5)....
-
1.4 Overview of Report
Section 6 briefly introduces the standard about which Committee members did not reach consensus: the minimum transfer surface height....
- Mannington Mills Against the Grain Collection Commercial Carpet
- Mesa Safe Company MHRC916E Electronic Hotel Safe
- Mesa Safe Company MH101E Electronic Hotel Safe
- Apex Challenge Circuit CH7000
-
Team and Player Seating
This provision, which derives from the Board’s guidelines for recreation facilities, requires at least one wheelchair space in team or player seating areas serving areas of sports activity...
-
2.2 Entrances
Once inside the building, is the accessible route to all public spaces at least 36 inches wide?...
-
4.5.4 Gratings
If gratings are located in walking surfaces, then they shall have spaces no greater than 1/2 in (13 mm) wide in one direction (see Fig. 8(g))....
-
4.28.2* Audible Alarms
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 dbA or exceeds any maximum sound level...
-
4.28.2* AUDIBLE ALARMS
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 decibels or exceeds any maximum sound level...