Exceptions: Open exit stairways as permitted by Section 1005.3.2 are permitted to be considered part of an accessible means of egress....
Search Results "General Exception"
Commonly Searched Documents
-
1003.2.13.2 Enclosed exit stairways
-
224.1.1 Alterations
EXCEPTION: Alterations to guest rooms in places of lodging where the guest rooms are not owned or substantially controlled by the entity that owns, leases, or operates the overall facility...
-
404.2.3 Clear Width
EXCEPTIONS: 1. In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear width shall be permitted for the latch side stop. 2....
-
405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due...
-
11B-202 Existing buildings and facilities
Exceptions: 4....
-
R302.3 Continuous Width
Except as provided in R302.3.1, the continuous clear width of pedestrian access routes shall be 1.2 m (4.0 ft) minimum, exclusive of the width of the curb....
-
405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due...
-
Areas of sport activity. (Section-by-Section Analysis)
Should the Department create an exception to this requirement for existing courts (e.g., tennis courts) that have been constructed back-to-back without any space in between them?...
-
402.2 Speech-Output Enabled
EXCEPTIONS: 1. Variable message signs conforming to 402.5 shall not be required to be speech-output enabled. 2....
-
907.2.9 Group R-2
Exceptions: A fire alarm system is not required in buildings not over two stories in height where all dwelling units and contiguous attic and crawl spaces are separated from each...
-
711.3.1 Through penetrations
Exception: Where the penetrating items are steel, fer- rous or copper pipes or steel conduits, the annular space between the penetrating item and the fire-resistance- rated wall shall be...
-
MANAGEMENT OF BEHAVIOR
Team play and sportsmanship cannot be taught except through participation. Effective PE and athletics require a teacher or coach with strong behavior management skills....
-
405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due...
-
Section 35.151 New Construction and Alterations (Section-by-Section Analysis)
This exception is now contained in the title III regulation and in the 1991 Standards (applicable to both public accommodations and facilities used by public entities), so it has applied...
-
703.4.2 Location
EXCEPTION: Signs with tactile characters shall be permitted on the push side of doors with closers and without hold-open devices. ...
-
604.8.1.4 Toe Clearance
EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than 62 inches (1575 mm) deep with a wall-hung water closet or 65 inches (1650 mm) deep with a floor-mounted...
-
221.2.3 Lines of Sight and Dispersion
EXCEPTION: Wheelchair spaces in team or player seating areas serving areas of sport activity shall not be required to comply with 221.2.3....
-
402.2 Components
., Florida requirements, except s.553.5041(5)(a) width of accessible route to parking and s.553.041(c)1 parking space and access aisle width, may be waived down to the requirements of the...
-
408.4.1 Car Dimensions and Doors
EXCEPTIONS: 1....
-
Guarantees of reservations for accessible guest rooms. (Section-by-Section Analysis)
When a public accommodation does guarantee hotel or other room reservations, it must provide the same guarantee for accessible guest rooms as it makes for other rooms, except that it must...
-
608.6 Shower Spray Unit and Water
EXCEPTION: A fixed shower head located at 48 inches (1220 mm) maximum above the shower finish floor shall be permitted instead of a hand-held spray unit in facilities that are not medical...
-
404.2.3 Doorways - Clear Width
EXCEPTIONS: 1. In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear width shall be permitted for the latch side stop. 2....
-
PART 1190 –ACCESSIBILITY GUIDELINES FOR PEDESTRIAN FACILITIES IN THE PUBLIC RIGHT-OF-WAY
Except for the International Symbol of Accessibility in Figure R411, which is included in the appendix to this part, the figures are for illustration purposes only and do not establish requirements...
-
404.2.3 Doorways - Clear Width
EXCEPTIONS: 1. In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear width shall be permitted for the latch side stop. 2....