1. General Exception
-
5.2.1.2 Transfer Surface Depth Recommendation for M301
Although the minimum size indicated by the SUNY research was 15 inches, current design practice used on tables and chairs incorporates a minimum depth of 17 inches....
-
Accessible Pathway & Corridor: Minimum Clear Floor Space Required for 360-degree Turn
A space of 210 x 210 cm (83 in.) was required in order for 95% of manual wheelchair and power chair users to complete the turn, with 95% of scooter users needing a space of at least 250...
-
3.3.8 Knee Clearance Depth, minimum
depth accommodated just over 50% of our overall sample, and was well below the 80th percentile values of maximum knee height for manual wheelchair users (369 mm or 14.5 in.) and power chair...
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 90-degree Turn
A width of 100 cm (39 in.) was required in order for 95% of manual wheelchair and power chair users to complete the turn, with 95% of scooter users needing a width of at least 110 cm (43...
-
Furnishings and Equipment
DOJ’s ADA regulations include requirements that may impact non-fixed elements, such as providing accessible medical equipment, including examination tables and chairs, to provide persons...
-
Exception 4
Rearranging tables, chairs, vending machines, display racks, and other furniture. Repositioning telephones. Adding raised markings on elevator control buttons....
-
Product Data and Unit Costs
Product data and unit costs for examination chairs and imaging equipment will be provided when the final standards are issued....
- Brewer Assist Power Procedure Table
- Sizewise SW Low Boy
- Delta Round Front Toilet C41901-WH
- SuperDeck Nature Trail
- Campion Marine Fishing Boat with Portable Power Lift
-
§ 382.21 Aircraft accessibility
movable or removable, adequate occupant restraint systems, a backrest height that permits assistance to passengers in transferring, structurally sound handles for maneuvering the occupied chair...
-
M303.2.3 Wheelchair Spaces / Depth of Wheelchair Spaces for front or Rear Entry
*The IDeA Center Study findings indicate that a 36 inch length accommodates standard manual and motorized wheelchairs and most, if not all, bariatric size- extra wide manual chairs IDeA...
-
About and Acknowledgements
June has a presidential appointment to the United States Access Board and has served as both its Vice Chair and Chair. To learn more about June, visit www.jik.com....
-
UDI
Of the 50 individuals studied, 35 used power chairs and 15 used scooters. The cause of disability for individuals in the sample included a wide range of conditions....
-
Scope: ADA Standard Section 201.1
Section 201 discusses the scope of the ADA Standards.
-
Wheelchair Space or Transfer Seat or Transfer Device
To permit maximum design flexibility, the 2010 Standards permit designers to determine whether it is more appropriate to permit individuals who use wheelchairs to remain in their chairs...
-
QUESTION: WHAT CONSIDERATIONS APPLY TO PVOs’ OBLIGATION TO PROVIDE ASSISTANCE TO PASSENGERS WITH DISABILITIES WITH RESPECT TO BOARDING AND DISEMBARKING FROM VESSELS?
., lifts, ramps, boarding chairs, assistance by PVO personnel in pushing a wheelchair or guiding a blind passenger)....
-
5. Recommendations
As discussed in Section 4.3, the requirements for diagnostic imaging equipment do not apply to patients in a seated (chair or wheelchair) when the imaging system is provided with and/or...
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn
A width of 170 cm (67 in.) was required in order for 95% of manual wheelchair and power chair users to complete the turn, with 95% of scooter users needing a width of at least 210 cm (83...
-
3.3.15.2 Side (lateral) reach - unobstructed
In order to accommodate over 90% of the manual and powered chair users, and over 80% of the scooter users in our sample, a shift from 380‒1220 mm (15‒48 in.) to 700‒1400 mm (27.5‒55 in.)...
-
1. Abdomen depth (AD)
Abdomen depth (AD) Abdomen depth was analyzed as the overall clearance depth beneath the mammography machine, and measured from the anterior-most aspect of the abdomen to the anterior-most...