Where the ramp width is less than the top landing width additional landing length may be necessary to accommodate handrail extensions required to be in the direction of the ramp run without...
Search Results "Curb Ramp Surface"
Commonly Searched Documents
- 
    
  
  11B-405.7.2.1
  
- 
    
  
  B. Interior Ramps
  Interior Ramps (1) Royal Street Entrance Interior Ramp - Defendants will rebuild this ramp so that it meets 2010 Standards §§ 206.2.4 and 405.... 
- 
    
  
  11B-305.2 Floor or ground surfaces
  Floor or ground surfaces of a clear floor or ground space shall comply with Section 11B-302.... 
- EZ-ACCESS Suitcase Singlefold AS Ramp
- 
    
  
  What if a locality is not resurfacing an entire block, but is resurfacing a crosswalk by itself?
  Regardless of whether there is curb-to-curb resurfacing of the street or roadway in general, resurfacing of a crosswalk also requires the provision of curb ramps at that crosswalk.... 
- 
    
  
  Floor Surfaces: ADA Standard Section 409.4.2
  Section 409.4.2 covers the current ADA Standards for the floor surfaces of private residence elevator cars. 
- 
    
  
  General: ADA Standard Section 405.1
  Section 405.1 of the ADA Standards covers information in the current ADA Standards for ramps. 
- 
    
  
  11B-405.1 General
  Ramps on accessible routes shall comply with Section 11B-405.... 
- 
    
  
  Handrails: ADA Standard Section 1008.2.5.3
  Where required on ramps serving play components, the handrails shall comply with 505 except as modified by 1008.2.5.3. EXCEPTIONS: 1.... 
- 
    
  
  Edge Protection [§405.9]
  Edge Protection [§405.9] Edge protection along ramp runs and landings keep wheelchair casters and crutch tips on the surface and can be provided by curbs, barriers, or extended surfaces... 
- 
    
  
  11B-406.5.1 Location
  Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles.... 
- 
    
  
  11B-406.5.1 Location
  Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles.... 
- 
    
  
  11B-406.5.1 Location
  Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles.... 
- 
    
  
  Ramps
  If any part of the accessible route - exterior or interior - has a slope greater than 1:20, it is considered a ramp and must meet the requirements for ramps.... 
- 
    
  
  11B-405.7.3.1
  Bottom landings shall extend 72 inches (1829 mm) minimum in the direction of ramp run.... 
- 
    
  
  1005.3.1 Curb or Barrier
  Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform.... 
- 
    
  
  1005.3.1 Curb or Barrier
  Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform.... 
- 
    
  
  Surface Smoothness
  The standards limit changes in level and openings in floor and ground surfaces, but they do not further address overall surface smoothness.... 
- 
    
  
  T302 Walking Surfaces
  The technical requirements for walking surfaces include provisions on slip resistance, the maximum size of surface openings, and the maximum height of vertical surface discontinuities (i.e... 
- Access Board: Accessible Parking Spaces and Access Aisles
- Seating Solutions ADA Platforms, Ramps & Stairs
- 
    
  
  Is there a limit on the total length (number of runs) a ramp may have?
  .), but not the overall length of ramps comprised of multiple runs. Since the usability of ramps decreases with length, considerably long ramp systems should be avoided where possible.... 
- 
    
  
  4.1.6(1)(f)
  (f) If an escalator or stair is planned or installed where none existed previously and major structural modifications are necessary for such installation, then a means of accessible... 
- 
    
  
  R302.7.2 Vertical Surface Discontinuities
  R302.7.2 Vertical Surface Discontinuities. Vertical surface discontinuities shall be 13 mm (0.5 in) maximum.... 