Each area of refuge shall be sized to accommodate one wheelchair space of 30 inches (762 mm) by 48 inches (1219 mm) for each 200 occupants or portion thereof, based on the occupant load...
Search Results "Bus Loading Zone"
-
1003.2.13.5.1 Size
-
11B-1008.2.5.3 Handrails
Exceptions: Handrails shall not be required on ramps located within ground level use zones. Handrail extensions shall not be required....
-
11B-1008.2.5.3 Handrails
Handrails shall not be required on ramps located within ground level use zones. 2. Handrail extensions shall not be required....
-
11B-1008.2.5.3 Handrails
Handrails shall not be required on ramps located within ground level use zones. 2. Handrail extensions shall not be required....
-
Gaps
Gaps Where wheelchair spaces are provided on amusement rides, the floors of rides must be coordinated with the floors of the load and unload areas so that when the ride is at the...
-
11B-206.7.7 Amusement rides
Platform lifts shall be permitted to provide accessible routes to load and unload areas serving amusement rides....
-
F206.7.7 Amusement Rides
Platform lifts shall be permitted to provide accessible routes to load and unload areas serving amusement rides....
-
206.7.7 Amusement Rides
Platform lifts shall be permitted to provide accessible routes to load and unload areas serving amusement rides....
-
11B-206.7.7 Amusement rides
Platform lifts shall be permitted to provide accessible routes to load and unload areas serving amusement rides. ...
-
11B-206.7.7 Amusement rides
Platform lifts shall be permitted to provide accessible routes to load and unload areas serving amusement rides....
-
206.7.7 Amusement Rides
Platform lifts shall be permitted to provide accessible routes to load and unload areas serving amusement rides....
-
F240.1 General
In existing play areas, where play components are relocated for the purposes of creating safe use zones and the ground surface is not altered or extended for more than one use zone, the...
-
240.1 General
In existing play areas, where play components are relocated for the purposes of creating safe use zones and the ground surface is not altered or extended for more than one use zone, the...
-
240.1 General
In existing play areas, where play components are relocated for the purposes of creating safe use zones and the ground surface is not altered or extended for more than one use zone, the...
-
R305.2.7 Boarding and Alighting Areas
R305.2.7 Boarding and Alighting Areas. At boarding and alighting areas at sidewalk or street level transit stops for rail vehicles, detectable warning surfaces shall be placed at the...
-
R308.1.1.1 Dimensions
R308.1.1.1 Dimensions. Boarding and alighting areas shall provide a clear length of 2.4 m (8.0 ft) minimum, measured perpendicular to the curb or street or highway edge, and a clear...
-
T503.2 Ramps and Bridgeplates
When ramps or bridgeplates are deployed, the walking surface shall be lighted with 2 foot-candles (22 lux) minimum of illumination.
-
T403 Lifts
[See subsections ...]
-
T402.10 Visual Contrast
The perimeter of the walking surface on ramps and bridgeplates shall be marked by a stripe. The stripe shall be 1 inch (25 mm) wide minimum and shall contrast visually with the rest...
-
R308.1.1 Boarding and Alighting Areas
R308.1.1 Boarding and Alighting Areas. Boarding and alighting areas at sidewalk or street level transit stops shall comply with R308.1.1 and R308.1.3. Where transit stops serve...
-
R308.1.3.1 Surfaces
R308.1.3.1 Surfaces. The surfaces of boarding and alighting areas and boarding platforms shall comply with R302.7. Advisory R308.1.3.1 Surfaces. Detectable warning surfaces are...
-
§ 37.201 Intermediate and rest stops
[See subsections ...]
-
§ 37.189 Service requirement for OTRB demand-responsive systems
[See subsections ...]
-
§ 37.193 Interim service requirements
[56 FR 45621, Sept. 6, 1991, as amended at 76 FR 57936, Sept. 19, 2011]