If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
Search Results "Floor-Level Exit Sign"
Commonly Searched Documents
-
4.2.5* Forward Reach
-
4.34.5.3 LAVATORY, MIRRORS, AND MEDICINE CABINETS
(3) If a medicine cabinet is provided above the lavatory, then the bottom of the medicine cabinet shall be located with a usable shelf no higher than 44 in (1120 mm) above the floor....
-
11B.707.7.1.3 Horizontally mounted display screen
from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor...
-
11B-802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
(1)(d)
Controls for flush valves should be mounted no more than 44 inches (1120 mm) above the floor....
-
§ 38.37(b)
(b) Controls required by paragraph (a) of this section shall be mounted no higher than 48 inches and no lower than 15 inches above the floor, shall be operable with one hand and shall not...
-
11B-802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
- Assisted Living Directory - Louisiana Assisted Living Facilities & Senior Care
-
903 Benches
Comments suggested clarifying that the clear floor or ground space is to be located parallel to the short axis of the bench. Response....
-
Conflict with Local Accessibility Codes
The commenter stated that the State of Washington's accessibility code may require installation of a ramp, and that the ramp may then create an accessible entrance for the ground floor,...
-
Highest and Lowest Heights Obtained
The 50th percentile participants were able to transfer to a simple platform (no grab bars or a backrest present) that was 28 inches high with respect to the floor and 14 inches low relative...
-
Circulation Paths
Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
-
II-5.5000 Historic preservation programs
ILLUSTRATION: Installing an elevator in an historic house museum to provide access to the second floor bedrooms would destroy architectural features of historic significance on the first...
-
11B-1008.2.3 Water play components
Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with Sections 11B-302 _|Floor or Ground...
-
1013.2 Where required
located along open-sided walking surfaces, including mezzanines, equipment platforms, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor...
-
11B-809.2.2 Turning space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
1118B.6
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 inches (1372 mm) and the low side reach shall be no less than...
-
E) Alternate Services
If a town meeting is scheduled to be held on the second floor of a building without an elevator and a person using a wheelchair wishes to attend the meeting, the meeting should be relocated...
-
G. Sleeping Areas
Accessible cots have a sleeping surface at approximately the same height above the floor as the seat of a wheelchair (17 to 19 inches above the floor)....
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
4.34.3(2)(b) Reach Depth More Than 10 in
Where the reach depth to the operable parts of any control as measured from the vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest protrusion...
-
4.8.5* HANDRAILS
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top and bottom of the ramp segment and shall be parallel with the floor or ground surface....
-
Suggestion by Eldon Tipping
Suggestion by Eldon Tipping As published in Concrete Construction magazine, September 1998, Eldon Tipping made suggestions for a specification for sloped random - traffic floors such as...