Grab bars may be mounted with any desired method as long as they have a gripping surface at the locations shown and do not obstruct the required clear floor area....
Search Results "Floor-Level Exit Sign"
Commonly Searched Documents
-
4.17.6 GRAB BARS
-
Are accessible spaces required in temporary parking lots and in unpaved lots, such as gravel or grass lots?
parking facilities, including gravel or grass lots, parking spaces and access aisles must be marked and have firm, stable, and slip resistant surfaces as specified for accessible ground and floor...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
§ 38.107(a)(4)
Controls for flush valves shall be mounted no more than 44 inches above the floor....
-
§ 38.123(a)(4)
Controls for flush valves shall be mounted no more than 44 inches above the floor....
-
11B.707.7.1.1 Vertically mounted display screen
mounted vertically or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
- Biodex BioStep® 2 Semi-Recumbent Elliptical Machine
-
Standing Supports (M304.3 and M305.3)
edge on the single entry ramp allows for enough coverage in length to assist the patient for stability to grab on both sides, to gain access to the platform for this one way entry and exit...
-
11B-410.1 General
Platform lifts shall not be attendant-operated and shall provide unassisted entry and exit from the lift. [2010 ADAS] Advisory 410.1 General. ...
-
D) Curb Ramps at Intersections
This type of curb ramp has flared sides and must be used when pedestrians may enter or exit the curb ramp from the side....
-
ADA Checklist for Existing Facilities
Copyright © 2017 ADA Checklist for Exiting Facilities. You can freely reproduce and distribute this content. Include proper attribution....
-
SUMMARY AND CONCLUSIONS
When traffic signals are installed that stop both entry and exit traffic at the same time while pedestrians cross both directions of traffic, queues back up into the circulating roadway...
-
ASME A18.1 Safety Standard [§410.1]
Under the ADA Standards, platform lifts must be independently operable and must allow unassisted entry and exit from the lift....
-
11B-410.1 General
Platform lifts shall not be attendant-operated and shall provide unassisted entry and exit from the lift. [2010 ADAS] Advisory 410.1 General....
-
11B-410.1 General
Platform lifts shall not be attendant-operated and shall provide unassisted entry and exit from the lift. Advisory 11B-410.1 General....
- Corbin Russwin Inc. Access 800 AC2 Electrified Door Hardware
- AquaTrek2 ADA Wading Pool Ramp
- Allegion Schlage LT Series Mechanical Locks with Tubular Interconnect
- Mannington Mills Palma Collection Commercial Carpet
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....