The phrase "to the maximum extent feasible," as used in this section, applies to the occasional case where the nature of an existing facility makes it virtually impossible to comply fully...
Search Results "Common Use Area"
-
[ADA Title III §36.402(c)] To the maximum extent feasible
-
11B-206.7.5 Existing site constraints
Platform lifts shall be permitted where existing exterior site constraints make use of a ramp or elevator infeasible. Advisory 11B-206.7.5 Existing site constraints....
-
11B-225.2.3 Library book stacks
Book stacks available for public use shall be 54 inches (1372 mm) maximum above the finish floor....
-
202.4.3 Series of smaller alterations
The obligation to provide an accessible path of travel may not be evaded by performing a series of small alterations to the area served by a single path of travel if those alterations could...
-
608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space....
-
608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space....
-
§ 36.304(d)(4)(i)
(i) Where an existing play area has less than 1000 square feet or is located in a family child care facility where the proprietor actually resides, it shall be exempt from the provisions...
-
§ 36.308(b) New construction and alterations
The provision and location of wheelchair seating spaces and companion seats and designated aisle seats in newly constructed or altered assembly areas shall be governed by the standards for...
-
§ 35.151(b)(4)(iv)(A)
(A) When the cost of alterations necessary to make the path of travel to the altered area fully accessible is disproportionate to the cost of the overall alteration, the path of travel shall...
-
11B-206.7.2 Wheelchair spaces
Platform lifts shall be permitted to provide an accessible route to comply with the wheelchair space dispersion and line-of-sight requirements of Sections 11B-221 _|Assembly Areas|_ and...
-
2.3 Restrooms
Is there a larger stall or an area in the restroom at least 36 inches in diameter and free from obstructions (trash cans, chairs, etc.)?...
-
Audio description
The text of the panel is narrated and exhibits in the surrounding area are described. Participant comments can be summarized as follows:...
-
§ 35.151(b)(4)(iv)(A)
(A) When the cost of alterations necessary to make the path of travel to the altered area fully accessible is disproportionate to the cost of the overall alteration, the path of travel shall...
-
11B-206.7.2 Wheelchair spaces
Platform lifts shall be permitted to provide an accessible route to comply with the wheelchair space dispersion and line-of-sight requirements of Sections 11B-221 _|Assembly Areas|_ and...
-
5.8.2.4 Unobstructed Floor Space Recommendation
To consider overall knee and toe clearance, the Committee used female-only anthropomorphic data that defined abdomen-toe depths to ensure that a patient’s toes would not hit the gantry....
-
How is slip resistance measured?
The most common device, the James machine, was developed in the early 1940s and was the testing device specified by the Underwriters Laboratory (UL) shortly thereafter when it established...
-
Paragraph (a) (Advisory Guidance)
For example, individuals who cannot see must use either touch or sound to locate and identify controls....
-
Access to Programs and Services in Existing Facilities
For example: If a social service agency meets with clients in a private office on the second floor of a building without an elevator, a public area on the first floor is not an acceptable...
-
Aisle Seats
Comments noted that this should apply only where armrests are provided on seats in the same area....
-
11B-405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by Sections 11B-404.2.4 and 11B-404.3.2 shall be permitted to overlap the required landing area....
-
Platform Edges
Since the sway of some rail cars may overlap a platform edge, the area of the detectable warning installation should not be considered a safety zone but rather an indication of an adjacent...
-
OBJECTIVES
This report summarizes topic areas that address issues of signalization of roundabouts to provide pedestrian access....
-
11B-405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by Sections 11B-404.2.4 and 11B-404.3.2 shall be permitted to overlap the required landing area....
-
Newly Constructed Tabled Intersections That Contain Pedestrian Street Crossings With Yield or Stop Control (Section-by-Section Analysis)
In new construction, street intersections in hilly urban areas are typically cut-and filled to produce relative flat or tabled intersections....