Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach?...
Search Results "Clear Floor Space"
Commonly Searched Documents
-
f-v
-
3. Bank of House Phones
If one house phone or one bank of house phones is provided on a given floor, does at least one house phone have the following features: [ADA Stds. 4.1.3(17)]...
-
8. Shower Curbs
Are the roll-in showers free of curbs or lips at the shower floor that would impede wheelchair approach and transfer onto the folding shower seat?...
-
K5
If the operating controls are set back 10 to 24 inches from the front edge of the counter or table are they no higher than 46 inches above the floor?...
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
A4.23.9 Medicine Cabinets
Shelves, drawers, and floor-mounted cabinets can be provided within the reach ranges of disabled people....
-
4.15.2* SPOUT HEIGHT
Spouts shall be no higher than 36 in (915 mm), measured from the floor or ground surfaces to the spout outlet (see Fig. 27(a))....
-
4.34.6.5(5)
The finished flooring shall extend under the counter to the wall....
-
A4.23.9 MEDICINE CABINETS
Shelves, drawers, and floor-mounted cabinets can be provided within the reach ranges of disabled people....
-
M303.4.1 Breast Platforms
The height of the breast platform shall be 30 inches (760 mm) high minimum and 42 inches (1065 mm) high maximum above the floor when in use by a patient seated in a wheelchair....
-
Handrail Extensions [§505.10]
Handrail Extensions [§505.10] Handrail extensions at the top and bottom must return to walls, guards, or floors and horizontal portions must comply as protruding objects....
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-225.3 Self-service storage facilities
Self-service storage facilities shall provide individual self-service storage spaces complying with these requirements in accordance with Table 11B-225.3....
-
3.7 Louisville Tinseltown 19, 4400 Towne Center Drive, Louisville, Kentucky
- In Auditorium 10, the four (4) wheelchair spaces shall be relocated one row farther back in the auditorium from their current location....
- Neo-Metro Commercial Metaal Toilet 8956 Series
- Neo-Metro Contour Commercial Stainless Steel Toilet 8955 Series
-
Islands [4.7.11]
At traffic islands, wheelchair space between opposing ramps is essential....
-
11B-502.6.4.1
11B-502.6.4.1 The parking space shall be marked with an International Symbol of Accessibility complying with Section 11B-703.7.2.1 in white on a blue background a minimum 36 inches wide...
-
11B-208.2.3.1 Parking for residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with Section 11B-502 shall be provided for each residential dwelling...
-
11B-208.2.3.1 Parking for residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with Section 11B-502 shall be provided for each residential dwelling...
-
Sloped Surfaces
Measuring the slope of a ramp, parking space, pedestrian route, or other ground or floor surface is important to identify whether the surface is accessible....
-
PART 4: ACCESSIBLE MEDICAL EQUIPMENT
Such equipment includes adjustable-height exam tables and chairs, wheelchair-accessible scales, adjustable-height radiologic equipment, portable floor and overhead track lifts, and gurneys...
-
Notes
Therefore, reducing the low height of the seat will increase the likelihood of the footplate colliding with the floor. ...