Section F205 of the ABA Standards requires operable parts in accessible spaces to comply with the technical requirements for operable parts in section 309 of the ABA Standards, including...
Search Results "Serving Space"
Commonly Searched Documents
-
Trailhead Information Signs [F216.13 and 1017.10]
-
Medical Device Manufacturers
size of transfer supports; • Question 23 (a) on stirrups; • Question 24 (b) on positioning supports; • Question 29 (a) on alternative dimension for minimum depth of wheelchair spaces...
-
Vanity Counter Tops
Requirements for accessible toilet and bathing rooms include a provision for vanity counter top spaces, which in the past have been omitted from accessible guest rooms even where provided...
-
Benches
Benches must have a clear floor space positioned to allow persons using wheelchairs or other mobility devices to approach parallel to the short end of a bench seat....
-
R302.7.1 Vertical Alignment
Vertical alignment shall be generally planar within pedestrian access routes (including curb ramp runs, blended transitions, turning spaces, and gutter areas within pedestrian access routes...
-
Saunas and steam rooms. (Section-by-Section Analysis)
Section 241 of the 2004 ADAAG requires newly constructed or altered saunas and steam rooms to meet accessibility requirements, including accessible turning space and an accessible bench....
-
Data Analysis
For protocols A, B and C percentages were calculated for the space needed to transfer to and from the transfer station....
-
Saunas and steam rooms. (Section-by-Section Analysis)
Section 241 of the 2004 ADAAG requires newly constructed or altered saunas and steam rooms to meet accessibility requirements, including accessible turning space and an accessible bench....
-
Completing the Checklist
For example, if there is no parking provided on-site at the polling place, or only on-street parking is provided, there is no need to try to measure the size of the parking spaces or to...
-
Gurney Accessible Bathroom
Movable wall for shower gurney access Vanity remodeled to clear the space for wheelchair users Hand-held shower 6’ hose on shower Shower heads at four...
-
Exception 4
Rearranging toilet partitions to increase maneuvering space. Insulating lavatory pipes under sinks to prevent burns. Installing a raised toilet seat....
-
11B-406.5.10 Diagonal curb ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway....
-
TECHNICALLY INFEASIBLE
alteration of a load-bearing member that is an essential part of the structural frame, or because other existing physical or site constraints prohibit modification or addition of elements, spaces...
-
804.2 Clearance
EXCEPTION: Spaces that do not provide a cooktop or conventional range shall not be required to comply with 804.2. Advisory 804.2 Clearance....
-
11B-220.1.2 Two automatic teller machines or fare machines
are provided at a location, one shall comply with Sections 11B-707.2 through 11B-707.8 and one shall comply with Sections 11B-309 _|Operable Parts|_, 11B-707.2 _|Clear Floor or Ground Space...
-
11B-208.2.3.3 Parking for guests, employees, and other non-residents
Where parking spaces are provided for persons other than residents, parking shall be provided in accordance with Table 11B-208.2....
-
F216.4.1 Exit Doors
An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or...
-
225.2 Storage
Where storage is provided in accessible spaces, at least one of each type shall comply with 811. Advisory 225.2 Storage....
-
219 Assistive Listening Systems
Section 219.2 requires an assistive listening system in each assembly area where audible communication is integral to the space and audio amplification is provided....
-
804.2 Clearance
EXCEPTION: Spaces that do not provide a cooktop or conventional range shall not be required to comply with 804.2. Advisory 804.2 Clearance....
-
216.4.1 Exit Doors
An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or...
-
Treads & Risers
...do the stairs have closed risers so a crutch or cane cannot slip through the open space between the stair risers and people will not lose their balance as they climb the stairs?...
-
Built-up Curb Ramps [4.7.6]
Built-up curb ramps are permitted where they do not project into vehicular traffic lanes or access aisles at parking spaces and passenger loading zones....
-
4.1.5 Accessible Buildings: Additions
Each space or element added to the existing building or facility shall comply with the applicable provisions of 4.1.1 to 4.1.3, Minimum Requirements (for New Construction) and the applicable...