Affected industries (floor finishes, ceramic tile, and plumbing fixtures) each employ a different testing method in designating the slip-resistance of their products....
Search Results "Clear Floor Area"
-
General [4.5.1]
- Sioux Chief Closet Flange Family Animation Video
-
11B-502.3.3 Marking
The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface, preferably blue or...
-
11B-502.3.3 Marking
The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface, preferably blue or...
-
Problem Five
The voting area and entrance to the voting area, however, are at the rear of the school and there are no designated accessible parking spaces in this area....
-
Problem Three
Solution: Find a parking area that is close to the accessible entrance and is level. ...
-
11B-206.7.9 Team or player seating
Platform lifts shall be permitted to provide accessible routes to team or player seating areas serving areas of sport activity. [2010 ADAS] Advisory 206.7.9 Team or Player Seating....
-
603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
-
709.4 Continuity
Smoke barriers shall form an effective membrane continuous from outside wall to outside wall and from floor slab to floor or roof deck above, including continuity through concealed spaces...
-
§ 36.404(a)(2)(ii)
(ii) A series of buildings on a common site, connected by a common pedestrian access route above or below the ground floor, that is either under common ownership or common control or developed...
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
Sec.36.404(a)(2)(ii)
(ii) A series of buildings on a common site, connected by a common pedestrian access route above or below the ground floor, that is either under common ownership or common control or developed...
-
603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
-
603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
-
[ADA Title II §35.151(b)(4)(i)] Primary function
Areas that contain a primary function include, but are not limited to, the dining area of a cafeteria, the meeting rooms in a conference center, as well as offices and other work areas in...
- SafePath VulcanLanding™ Rubber Transition Ramp
-
L. Controls
Are all drapery control wands, fixed lamps and HVAC controls in accessible guestrooms placed within 54" of the floor for side approach or 48" of the floor for forward approach so persons...
-
4.34.6.4(1)
(1) The counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable or replaceable as...
-
Kitchens and Kitchenettes
Section 4.34.2 of the UFAS requires a clear turning space at least 60 inches in diameter or an equivalent T-shaped turning space in kitchens....
-
Section 6.0 Conclusions
Clear floor space: A large minority of participants in our research would not be accommodated by the current U.S. standard for clear floor space, especially for length....