Where at least one public pay telephone is provided on a floor of a public building, at least one public TTY shall be provided on that floor....
Search Results "Shower Clear Floor Space"
Commonly Searched Documents
-
11B-217.4.2.1 Public buildings
-
11B-405.9.1 Reserved
[2010 ADAS] 405.9.1 Extended Floor or Ground Surface....
-
Typical examples of reasonable modifications are:
a health club to allow a person who uses a wheelchair to bring an aide to provide assistance in getting on and off exercise equipment, in and out of a swimming pool, or to assist with showering...
-
4.20.4 Grab Bars
In fact, in instances where local building authorities required bathing fixtures with ADAAG compliant grab bar configurations, roll-in showers were installed instead due to safety concerns...
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
The MDE NPRM proposed certain clearance requirements beneath the diagnostic equipment to allow sufficient space for the legs of a portable patient lift to fit underneath the equipment so...
- Mannington Mills Allegiant Collection Commercial Carpet
-
F - number system
F - number system The F - number system, ASTM E 1155, Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers, was developed primarily to aid in the construction...
-
Vertical Clearance: ADA Standard Section 502.5
Section 502.5 covers the current ADA Standards for the vertical clearance required at accessible parking spaces.
-
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191 Bus boarding and alighting areas shall provide a clear length of 96 inches (2440 mm), measured perpendicular...
-
1015.2 Where required
along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor...
-
11B-405.9.1 Reserved
[2010 ADAS] 405.9.1 Extended Floor or Ground Surface. ...
-
11B-405.9.1 Reserved.
[2010 ADA Standards] 405.9.1 Extended Floor or Ground Surface....
-
EXTREME WEATHER
Cooling centers are air conditioned spaces such as senior centers, community centers, public libraries, and other public facilities that typically operate during daytime hours and are free...
-
Exception 9
Certain types of privately funded, multistory buildings and facilities were formerly exempt from accessibility requirements above and below the first floor under this code, but as of, April...
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar with the opening of the disposal unit 19 inches minimum (483 mm) above the finish floor....
-
11B-407.2.2.1 Visible and audible signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. Exceptions: Reserved. Reserved....
-
11B-407.2.1.1 Height
[2010 ADA Standards] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground....
-
CCDA Accessibility Checklist for Building Inspectors, 2015 Edition
During construction inspection finish product thicknesses such as flooring materials or wall coverings must be considered when reviewing critical accessibility features, including but not...
- Pilot Rock UT Series Side Accessible Picnic Table Using Aluminum
- Pilot Rock XT Series Side Accessible Picnic Table Using Aluminum
-
Overhead Lifts
Overhead lifts and portable floor lifts are used in health care facilities, and the technical criteria should not be viewed as preferring portable floor lifts....
-
Alterations: ADA Standard Section 202.3
Section 202.3 covers the most current requirements for alterations in existing building and facilities.