Does each accessible toilet have a horizontal grab bar on the adjacent side wall that is at least 40" long and between 33"-36" above the floor for stabilization and assistance during transfer...
Search Results "Floor-Level Exit Sign"
Commonly Searched Documents
-
E. Grab Bars
-
F. Grab Bars
Does each accessible toilet have a horizontal grab bar on the wall behind the toilet that is at least 36" long and between 33"-36" above the floor for stabilization and assistance during...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
306.3.4 Clearance Reduction
Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
803.5 Coat Hooks and Shelves
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
407.12.3.1 Unobstructed Forward Reach
maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
-
1133A.2, Item 2
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other fixtures or appliances...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B.707.7.1.3 Horizontally mounted display screen
from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor...
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
-
M301.3.1 Transfer Supports
Figure 5.3-10: Illustration of a concept (not to scale) for a detachable floor mounted support....
-
Passing Spaces [1017.4]
Where the trail is heavily used or the trail is not at the same level as the adjoining ground surface, such as a bridge crossing a ravine, increasing the frequency of passing spaces or widening...
-
Tips for Interacting with People with Disabilities
If the person uses a sign language interpreter, speak directly to the person, not to the interpreter....
-
III-4.3600 Limitations and alternatives
ILLUSTRATION: It may be an undue burden for a small private historic house museum on a shoestring budget to provide a sign language interpreter for a deaf individual wishing to participate...
-
Stabilizer
It was not until the testing conducted in March 2008 that the surface showed large signs of deterioration....
- Panda TS.87 Thermally Broken Slim Profile Lift & Slide System
- Panda TS.19 Thermally Broken Lift & Slide System
-
5.0 Conclusions
At least in facilities that are frequented by international travelers, minimum requirements for key built elements would provide a basic level of accessibility that everyone could expect...
- Tile Tech Pavers® Porcelain Pavers™ Series
- Wilkinson Hi-Rise Trash Chute
-
604.8.3 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. [ECTCR UFAS 4.25.3, Fig. 38, 4.23.9, 4.34.5.3(3)]...
-
11B-804.3.2 Height
The kitchen work surface shall be 34 inches (864 mm) maximum above the finish floor or ground....
-
1007.8.2 Directions
Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the specific story, floor...
-
405.9.2 Curb or Barrier
A curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or ground...