Additional requirements for emergency communication systems are not included in the final rule....
Search Results "Nurse Call System"
-
Emergency Communication
-
NOTIFICATION
Action Steps: Notification Provide ways to inform people who are deaf or hard of hearing of an impending disaster if you use emergency warning systems such as sirens or other audible...
-
10.4.1(6)
(6) Terminal information systems which broadcast information to the general public through a public address system shall provide a means to provide the same or equivalent information to...
-
How ALSs Operate
How ALSs Operate Like public address systems, ALSs convert live or recorded sound into an electromagnetic signal....
-
R211.1 General
Where audible sign systems and other technologies are used to provide information equivalent to the information contained on pedestrian signs and transit signs, the signs are not required...
-
703.7.2.4 Assistive Listening Systems
703.7.2.4 Assistive Listening Systems. Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss complying with Figure 703.7.2.4....
-
T603 Wheelchair Securement Systems
securement systems....
- Ampetronic ILD100 Small Area, VOX Switching Audio Induction Loop Driver Hearing System
-
11B-223 Medical care and long-term care facilities
Where physician or staff on-call sleeping rooms are provided, at least 10 percent, but no fewer than one, of the on-call rooms shall provide mobility features complying with Sections 11B...
-
11B-407.2.2.2 Visible signals
Signals shall be visible from the floor area adjacent to the hall call button. Exceptions: 1. Reserved. 2. Reserved. [2010 ADAS] 2....
-
11B-407.2.2.2 Visible signals
Signals shall be visible from the floor area adjacent to the hall call button. Exceptions: Reserved. Reserved. [2010 ADA Standards] 2....
-
Transfer Platform
Transfer Platform Each transfer system must have a platform on the deck surface so users can maneuver on and off the system from their mobility device or wheelchair....
-
907.2.1 Group A
A manual fire alarm system shall be installed in accordance with NFPA 72 in Group A occupancies having an occupant load of 300 or more....
-
11B-407.2.2.2 Visible signals
Signals shall be visible from the floor area adjacent to the hall call button. Exceptions: 1. Reserved. 2. Reserved. [2010 ADAS] 2. ...
-
11B-810.7 Public address systems
Where public address systems convey audible information to the public, the same or equivalent information shall be provided in a visual format....
-
11B-810.7 Public address systems
Where public address systems convey audible information to the public, the same or equivalent information shall be provided in a visual format....
-
11B-810.7 Public address systems
Where public address systems convey audible information to the public, the same or equivalent information shall be provided in a visual format....
-
§ 37.31 Vanpools
Vanpool systems which are operated by public entities, or in which public entities own or purchase or lease the vehicles, are subject to the requirements of this part for demand responsive...
-
907.2.1.1 System initiation in Group A occupancies with an occupant load of 1,000 or more
Activation of the fire alarm in Group A occupancies with an occupant load of 1,000 or more shall initiate a signal using an emergency voice/alarm communications system in accordance with...
-
Peak Clipping Level: ADA Standard Section 706.6
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
Handsets: ADA Standard Section 708.3
Handset cords, if provided, shall be 29 inches (735 mm) long minimum.
-
11B-708.3 Handsets
Handset cords, if provided, shall be 29 inches (737 mm) long minimum.
-
11B-706.6 Peak clipping level
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
11B-708.3 Handsets
Handset cords, if provided, shall be 29 inches (737 mm) long minimum.