An agency may conclude that EIT meeting the applicable technical provisions of the Access Board’s standards is not available (and purchase EIT that does not meet those provisions)...
Search Results "NTTAA: National Technology Transfer and Advancement Act of 1995"
-
F.1. - Under what circumstances may an agency conclude that no EIT is available that meets the Access Board’s technical provisions?
-
E203 Access to Functionality (Section-by-Section Analysis)
E203 Access to Functionality (Section-by-Section Analysis) This is an introductory section.
-
508 Chapter 2: Scoping Requirements (Section-by-Section Analysis)
This chapter proposes scoping for ICT that is procured, developed, maintained or used by federal agencies—that is, the types of ICT that would be required to conform to the proposed...
-
407.2 Contrast (Section-by-Section Analysis)
407.2 Contrast (Section-by-Section Analysis) This section proposes that keys and controls, where provided, contrast visually from background surfaces. Characters and symbols would...
-
E203 Access to Functionality
[See subsections ...]
-
508 CHAPTER 2: SCOPING REQUIREMENTS
[See subsections ...]
-
CHAPTER 5: SOFTWARE
[See subsections ...]
-
CHAPTER 4: HARDWARE
[See subsections ...]
-
401 General
[See subsections ...]
-
403 Biometrics
[See subsections ...]
-
407.2 Contrast
Where provided, keys and controls shall contrast visually from background surfaces. Characters and symbols shall contrast visually from background surfaces with either light...
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. Figure 1009.4.2 Transfer Wall Height...
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck. FIGURE 11B-1009.4.2 TRANSFER WALL HEIGHT...
-
1. Adoption of the 2010 ADA Standards for Accessible Design
minimize compliance burdens on entities subject to more than one legal standard, these design standards have been harmonized with the Federal standards implementing the Architectural Barriers Act...
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. Figure 1009.4.2 Transfer Wall Height...
-
National Accessibility Code
These commenters requested that the Department work with the individual States to arrive at one national uniform set of accessibility guidelines. Response....
-
Air Carrier Access Act
The Air Carrier Access Act prohibits discrimination in air transportation by domestic and foreign air carriers against qualified individuals with physical or mental impairments....
-
A. Proposed 508 Standards
By applying a single set of requirements to websites, electronic documents, and software, this proposed provision would adapt the 508 Standards to reflect the newer multifunction technologies...
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
§ 1194.1 Standards for Section 508 of the Rehabilitation Act.
The standards for information and communication technology developed, procured, maintained, or used by Federal agencies covered by Section 508 of the Rehabilitation Act are set forth in...
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers....
- Part 15- Save, Transfer & Restore a Backup Using iTunes for Mac OS X