907.2.6 Group I
A manual fire alarm system and an automatic fire detection system shall be installed in Group I occupancies....
- TSA Cares: Special Procedures - Disabilities & Medical
-
Appendix D: Photometric Measurements
In the field it is possible to calculate reflectance factor of a detectable warning (RDW) by measuring the luminance of the detectable warning (LDW) and the luminance of a standard white...
-
11B-247.1.2.3 Islands or cut-through medians
Islands or cut-through medians shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.3. ...
-
11B-247.1.2.3 Islands or cut-through medians
Islands or cut-through medians shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.3....
-
11B-247.1.2.3 Islands or cut-through medians
Islands or cut-through medians shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.3....
-
Protruding Objects
Protruding Objects: Some people who are blind or have low vision use canes to detect objects along a route....
-
11B-406 Curb ramps, blended transitions and islands
Islands are addressed at 2010 ADAS 406.7, almost identical to CBC, except for detectable warnings. See also U.S. Access Board's Note to Reader at Detectable Warnings....
-
Re: Co-sharing of Accessible Parking access Aisles by adjacent elevator door allowed?
How would you address the requirement for detectable warnings? Changes in level are not permitted in access aisles. 2016 CBC 11B-247.1.2.5, 11B-502.4...
-
11B-406 Curb ramps, blended transitions and islands
Islands are addressed at 2010 ADA Standards 406.7, almost identical to CBC, except for detectable warnings. See also U.S. Access Board's Note to Reader at Detectable Warnings....
-
ColorVisionTesting
You will learn about a new "pediatric" color vision test for early detection. If you think you may be colorblind, you can test your color vision on-line here for free....
-
809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation....
-
809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation....
-
11B-406 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS
Islands are addressed at 2010 ADAS 406.7, almost identical to 2013 CBC, except for detectable warnings. See also U.S. Access Board's Note to Reader at Detectable Warnings....
-
907.2.6.2.3 Smoke detectors
An approved automatic smoke detection system shall be installed throughout resident housing areas, including sleeping areas and contiguous day rooms, group activity spaces and other common...
-
Individuals with Partial or Total Vision Loss
Pedestrians with vision loss who use canes will follow edges to travel, while those who use dog guides typically use audible, tactile, and environmental cues in lieu of vision for obstacle detection...
- Norton 6000 Series Low Energy Operator
-
809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation....
- Delta Toilet with FlushIQ Technology
-
A10.3.1(7) Route Signs
Those activated by a mechanical motion are likely to be more detectable....
-
11B-304.2 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-304.2 Floor or ground surface Exception....
-
11B-304.2 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-304.2 Floor or ground surface Exception....
-
809.5.1 Building Fire Alarm System
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke detection...