Interior signage shall be located alongside the door on the latch side and shall be mounted at a height of between 54 in and 66 in (1370 mm and 1675 mm) above the finished floor....
Search Results "Interior Lighting"
Commonly Searched Documents
-
4.30.6 MOUNTING LOCATION AND HEIGHT
-
§100.201 Public use areas
Public use areas means interior or exterior rooms or spaces of a building that are made available to the general public....
-
4.3.2(4)
(4) An accessible route shall connect at least one accessible entrance of each accessible dwelling unit with those exterior and interior spaces and facilities that serve the accessible dwelling...
-
Common Use
Refers to those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, occupants of a homeless shelter, the occupants...
-
68.10(17) Overall Responsibility
(17) Overall Responsibility--The level of responsibility held by an architect, interior designer, landscape architect or engineer who prepares construction documents and coordinates the...
-
§ 37.83(d)
(d) If a public entity operates a rapid or light rail system any segment of which is included on the National Register of Historic Places and if making a rapid or light rail vehicle of historic...
-
A. Fire Alarms
If the building has an audible fire alarm system, do each of the following rooms in the hotel have a visual alarm strobe light mounted on the wall at 80" above the floor to alert deaf persons...
- ADA Checklist for Existing Facilities
-
1011.4, Item 4
Each exit access door from an interior room or area to a corridor or hallway that is required to comply with Section 1011.1, shall be identified by a tactile exit sign with the words “EXIT...
-
Joint Use
Interior or exterior rooms, spaces, or elements that are common space available for use by all occupants of the building....
-
Sec. 469.102(a)
(a) The architect, interior designer, landscape architect, or engineer who has overall responsibility for the design of a constructed or reconstructed building or facility shall submit the...
-
COMMON USE
Refers to those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, residents of an apartment building, the...
-
1013.4, Item 4
Each exit access door from an interior room or area to a corridor or hallway that is required to comply with Section 1013.1, shall be identified by a tactile exit sign with the words “EXIT...
-
Plan the room set-up
□ Plan the room set-up to accommodate people with disabilities and equipment for accessibility (seats, space between rows and desks, entrance, egress, lighting, acoustics, accessible podiums...
-
A4.29.2 Detectable Warnings on Walking Surfaces
Contrast in percent is determined by: Contrast = [(B1 - B2)/B1] x 100 where B1 = light reflectance value (LRV) of the lighter area and B2 = light reflectance value (LRV) of the darker...
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
The color of the circle symbol shall contrast with the color of the door or surface on which the circle symbol is mounted, either light on a dark background or dark on a light background...
-
§ 38.105(b)
an upper case “X”) of 5/8 inch, with “wide” spacing (generally, the space between letters shall be 1/16 the height of upper case letters), and shall contrast with the background either light-on-dark...
-
11B-233.3.1.2.6.5 Additional requirements.
Interior door opening width complying with Section 11B-404.3.1. 3. Door and gate hardware complying with Section 11B-404.2.7. 4....
-
Are exterior stairs required to comply with the Standards?
The Standards apply to both exterior and interior stairs that are part of a required means of egress....
-
407.2 Contrast (Section-by-Section Analysis)
Characters and symbols would have to provide this contrast with either light characters or symbols on a dark background or dark characters or symbols on a light background....
-
Transit Facilities: Rail Stations
It applies to new and altered rapid, light, commuter, and intercity rail stations....
-
II. Color Contrast—Step Edges, Lift Platform Edges
Contrast in percent is determined by: Contrast=[B−B)/B]×100 Where B=light reflectance value (LRV) of the lighter area and B=light reflectance value (LRV) of the darker area....
-
§ 38.27(c)
an upper case “X”) of 5/8 inch, with “wide” spacing (generally, the space between letters shall be 1/16 the height of upper case letters), and shall contrast with the background either light-on-dark...
-
§ 38.55(b)
an upper case “X”) of 5/8 inch, with “wide” spacing (generally, the space between letters shall be 1/16 the height of upper case letters), and shall contrast with the background, either light-on-dark...