- BEA Inc. LZR-Microscan Swinging Door Sensor
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
Section D: Entrances
Ward:__________ Precinct:__________ Staff:________________ Date:________ Time:_________ Address:_______________________________________ Location name:______________________...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
Smooth Surface
Exceptions from this requirement are recognized for sliding doors (Exception 1), certain tempered glass doors without stiles (Exception 2), doors and gates that do not extend to within 10...
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
11B-213.3.1.2 Toilet compartments with urinal compartments
At all compartments not required to comply with Section 11B-604.8 or Section 11B-605.5, compartment doors shall be in-swinging and self-closing....
-
11B-213.3.1.2 Toilet compartments with urinal compartments
At all compartments not required to comply with Section 11B-604.8 or Section 11B-605.5, compartment doors shall be in-swinging and self-closing....
-
4.1.2(7)
(7) Doors: (a) At each accessible entrance to a building or facility, at least one door shall comply with 4.13....
-
Re: 404.2.6 Doors in Series and Gates in Series
My understanding is that it was written to keep wheelchair users from having to fight two doors at once. ...
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
Entrances
space beyond the latch side of the door....
-
Are spring hinges and gravity hinges considered “closers” in determining the size of maneuvering clearances?
Some approaches require additional maneuvering clearances when a door or gate is equipped with a closer because of the additional force that must be counteracted in proceeding through doors...
-
Technical Memorandum TM 2017-25 Door and Gate Surfaces
TAS 404.2.10 also includes Exceptions for (1) sliding doors, (2) tempered glass doors (3) doors and gates which do not extend to within 10 inches of the finish floor, and (4) existing doors...
-
410.6.3 Interoperability (Section-by-Section Analysis)
410.6.3 Interoperability (Section-by-Section Analysis) This section proposes that, where ICT with real-time two-way voice communication operates outside of a closed network or connects...
-
H25
Is the clear width of the door at least 32 inches (measured between the face of the door and the edge of the opening) when the door is open 90 degrees?...
-
Floor or Ground Surface: ADA Standard Section 404.2.4.4
Section 404.2.4.4 covers the current ADA Standards for floor or ground surfaces at door maneuvering clearances.