Section 306.2.3 covers the current ADA Standards for the minimum required depth for toe clearance.
Search Results "Clear Floor Area"
-
Minimum Required Depth: ADA Standard Section 306.2.3
-
11B-902.2 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided....
-
11B-902.2 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided....
-
11B-902.2 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided....
-
707.2 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided....
-
707.2 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided....
-
Floor or Ground Surface: ADA Standard Section 802.1.1
The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
11B-1007.3.2 Golf club reach range area
All areas within holes where golf balls rest shall be within 36 inches (914 mm) maximum of a clear floor or ground space 36 inches (914 mm) wide minimum and 48 inches (1219 mm) long minimum...
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
11B-1007.3.2 Golf club reach range area
All areas within holes where golf balls rest shall be within 36 inches (914 mm) maximum of a clear floor or ground space 36 inches (914 mm) wide minimum and 48 inches (1219 mm) long minimum...
-
11B-1007.3.2 Golf club reach range area
All areas within holes where golf balls rest shall be within 36 inches (914 mm) maximum of a clear floor or ground space 36 inches (914 mm) wide minimum and 48 inches (1219 mm) long minimum...
-
J2
If the drinking fountain is a floor-mounted unit, is there clear floor space at least 30 inches long x 48 inches wide (60 inches if it is in an alcove) for a side approach to the drinking...
-
3.4.6 Surface
The surface of each viewing area shall be firm and stable. The type of surface should be appropriate to the setting and level of development. ...
-
FUNCTIONAL AREA
[DSA-AC] A room, space or area intended or designated for a group of related activities or processes....
-
FUNCTIONAL AREA
[DSA-AC] A room, space or area intended or designated for a group of related activities or processes....
-
AREA OF REFUGE
An area where persons unable to use stairways can remain temporarily to await instructions or assistance during emergency evacuation....
-
AREA OF REFUGE
An area where persons unable to use stairways can remain temporarily to await instructions or assistance during emergency evacuation....
-
6c.
Is there at least a 30-inch by 48-inch clear floor space on the wheelchair lift? Yes _____ No _____...
-
§ 38.123(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches....
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...
-
T502.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (810 mm) minimum....
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....