The slope of the clear floor or ground space required by section 4.6.4 shall not exceed 1:48 (2 percent) in any direction. Exception....
Search Results "Clear Floor Area"
Commonly Searched Documents
-
4.6.5 Slope
-
11B-707.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-707.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....
-
4.1.5 Slope
The slope of the surface of the clear floor or ground space around a picnic table shall not exceed 1:48 (2 percent) in any direction. Exception....
-
8.2 Reading and Study Areas
At least 5 percent or a minimum of one of each element of fixed seating, tables, or study carrels shall comply with 4.2 and 4.32. Clearances between fixed accessible tables and...
-
8.2 READING AND STUDY AREAS
At least 5 percent or a minimum of one of each element of fixed seating, tables, or study carrels shall comply with 4.2 and 4.32. Clearances between fixed accessible tables and study...
-
11B-604.3.2 Overlap
clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear...
-
11B-405.5 Clear width
Exceptions: Within employee work areas, the required clear width of ramps that are a part of common use circulation paths shall be permitted to be decreased by work area equipment...
-
11B-1008.2.4 Clear width
Accessible routes connecting play components shall provide a clear width complying with Section 11B-1008.2.4....
-
Living and Dining Areas: ADA Standard Section 806.2.1
Living and dining areas shall be accessible....
-
604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with 604.3.
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear...
-
604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with 604.3.
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear...
-
J. Transfer Space
J. If there is a lavatory in the accessible stall, is there 42" between the center of the toilet and the near edge of the adjacent lavatory to permit persons with disabilities to...
-
604.3.1 Size
604.3.1 Size. Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular...
-
604.3 Clearance
604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with 604.3.
-
Water Closet Clearances
The Department gave careful consideration to the costs and benefits of its adoption of the standards relating to water closet clearances in single-user toilet rooms. The primary...
-
11B-604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3.
-
A4.2 Space Allowances and Reach Ranges
[See subsections ...]
-
604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with 604.3.
-
A4.2 SPACE ALLOWANCES AND REACH RANGES
[See subsections ...]
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear...