Subpart A—General §1192.3 – [Amended] 2. Amend § 1192.3 as follows: a. In the definition of “Bus,” remove the phrase “other than an over-the-road bus,”; and b....
Search Results "General Exception"
-
36 CFR Part 1192 Americans with Disabilities Act (ADA) Accessibility Guidelines for Transportation Vehicles (2016 Non-Rail Vehicle Guidelines)
-
Door and Gate Surfaces: ADA Standard Section 404.2.10
Section 404.2.10 covers the current ADA Standards for door and gate surfaces on manual doors and gates.
-
Outdoor Developed Areas: ADA Standard Section 9.
Review the updated information on the revisions to the ADA Standards regarding outdoor developed areas.
-
11B-703.3.1 Dimensions and capitalization
ETA Editor's Note Table 11B-703.3.1 in CBC is the same as Table 703.3.1 in 2010 ADA Standards, except for distance between dots in the same cell or adjacent cells. 2010 ADA Standards...
-
1010.2.13.1 Delayed egress locking system
Exception: In facilities housing Alzheimer's or dementia clients, a delay of not more than 30 seconds is permitted on a delayed egress door. … 6....
-
11B-208.2 Minimum number
Parking spaces complying with Section 11B-502 shall be provided in accordance with Table 11B-208.2 except as required by Sections 11B-208.2.1, 11B-208.2.2, and 11B-208.2.3....
-
11B-609.3 Spacing
Exceptions: The space between the grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 1½ inches (38 mm) minimum....
-
11B-809.12 Electrical receptacles, controls and switches
Exceptions: a. Electrical receptacles installed as part of permanently installed baseboard heaters. b. Electrical receptacles in floors adjacent to sliding panels or walls....
-
11B-608.3 Grab bars
Exceptions: 1. Reserved. [2010 ADA Standards] 1....
-
11B-809.12 Electrical receptacles, controls and switches
Exceptions: a. Electrical receptacles installed as part of permanently installed baseboard heaters. b. Electrical receptacles in floors adjacent to sliding panels or walls....
-
11B-608.3 Grab bars
Exceptions: 1. Reserved. [2010 ADA Standards] 1....
-
1015.2 Where required
Exception: Guards are not required for the following locations: On the loading side of loading docks or piers....
-
1010.2.12.1 Delayed egress locking system
Exception: In facilities housing Alzheimer's or dementia clients, a delay of not more than 30 seconds is permitted on a delayed egress door. … 6....
-
11B-609.3 Spacing
Exceptions: The space between the grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 1½ inches (38 mm) minimum....
-
11B-703.3.1 Dimensions and capitalization
ETA Editor's Note Table 11B-703.3.1 in CBC is the same as Table 703.3.1 in 2010 ADA Standards, except for distance between dots in the same cell or adjacent cells. 2010 ADA Standards...
-
11B-208.2 Minimum number
Parking spaces complying with Section 11B-502 shall be provided in accordance with Table 11B-208.2 except as required by Sections 11B-208.2.1, 11B-208.2.2, and 11B-208.2.3....
-
Condition, Manner, or Duration Examples, Including Negative Effects of Mitigating Measures
Another commenter sought guidance on the specific reference points that should be used when drawing comparisons with most people in the general population....
-
11B-407.2.2.3 Audible signals
Exceptions: 1. Reserved. 2. Reserved. [2010 ADAS] 2. ...
-
410.6 Doors and Gates
EXCEPTION: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
1007.2.1 Elevators required
Exceptions: 1. ...
-
11B-705.1.2.3 Islands or cut-through medians
Exception: Detectable warnings shall be 24 inches (610 mm) minimum in depth at pedestrian islands or cut-through medians that are less than 96 inches (2438 mm) in length in the direction...
-
11B-410.6 Doors and gates
Exception: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
11B-211.3 More than minimum number
Exception: Where 50 percent of the drinking fountains yields a fraction, 50 percent shall be permitted to be rounded up or down provided that the total number of drinking fountains complying...
-
1008.2.4.2 Elevated
EXCEPTIONS: 1....