Exceptions: 1. Exterior ground floor exits serving smoke-proof enclosures, stairwells, and exit doors serving stairs only shall not be required to comply with Section 11B-404. 2. ...
Search Results "General Exception"
Commonly Searched Documents
-
11B-206.4.1 Entrances and exterior ground floor exits
-
11B-233.3.4.2 Alterations to individual residential dwelling units
Exception: Where public housing facilities contain 15 or fewer residential dwelling units, the requirements of Sections 11B-233.3.1.1, 11B-233.3.1.2, and 11B-233.3.1.3 shall apply to the...
-
11B-604.8.1.1 Size
When deployed the baby changing tables shall not obstruct the required width of the accessible route except as allowed by Section 11B-307.2....
-
11B-206.4.1 Entrances and exterior ground floor exits
Exceptions: Exterior ground floor exits serving smoke-proof enclosures, stairwells, and exit doors serving stairs only shall not be required to comply with Section 11B-404....
-
11B-242.2 Swimming pools
. ◼ Exceptions: 1....
-
1009.5.7 Grab Bars
EXCEPTION: Grab bars on transfer systems shall not be required to comply with 609.4. Figure 1009.5.7 Grab Bars...
-
F216.2 Designations
EXCEPTION: Exterior signs that are not located at the door to the space they serve shall not be required to comply with 703.2. Advisory F216.2 Designations....
-
Accessible Routes in Dwelling Units with Mobility Features
Section 233.3.5 of the 2010 Standards also includes an exception to the dispersion requirement that permits accessible single-story dwelling units to be constructed, where multi-story dwelling...
-
1016.5 Obstacles
EXCEPTION: Where the surface is other than asphalt, concrete, or boards, obstacles shall be permitted to not exceed 1 inch (25 mm) in height measured vertically to the highest point....
-
11B-705.1.2.2 Curb ramps
Exception: On parallel curb ramps, detectable warnings shall be placed on the turning space at the flush transition between the street and sidewalk....
-
1007.6.1 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 48 inches (762 mm by 1219 mm)...
-
382.35 May carriers require passengers with a disability to sign waivers or releases?
Carriers must not impose requirements or restrictions on passengers with a disability that they do not impose on other passengers, except where this regulation explicitly permits the carrier...
-
Forward Approach
An existing exception for units designed specifically for children’s use permits a parallel approach if certain criteria for spout height and location are met....
-
Accessible Check-out Aisle Signage
This provision, which is reformatted as an exception in the final rule, has been revised to apply where "all check-out aisles serving a single function" are accessible....
-
211 and 602 Drinking Fountains
The 2010 Standards require drinking fountains mounted at a height for wheelchair users to provide clear floor space for a forward approach with knee and toe clearance, and include an exception...
-
11B-225.2.3 Library book stacks
Exceptions: 1. ...
-
Two Drinking Fountains
Single units that provide both types of access are permitted as an alternative to multiple installations (211.2 Exception)....
-
F206.2.2 Within a Site
EXCEPTION: An accessible route shall not be required between accessible buildings, accessible facilities, accessible elements and accessible spaces if the only means of access between them...
-
608.3 Grab Bars
[ECTCR UFAS 4.21.4, Fig. 37, 4.34.5.5(3), Fig. 49] EXCEPTIONS: 1....
-
Sloped Entries
Sloped Entries Sloped entries must comply with ADAAG accessible route provisions (36 inch minimum width, maximum 1:12 or 8.33% slope), except that the surface does not need to be slip...
-
221.2.3.1 Horizontal Dispersion
EXCEPTIONS: 1....
-
604.3.2 Overlap
EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum from the water closet centerline where the clearance...
-
408.4.1 Car Dimensions and Doors
EXCEPTIONS: 1....
-
407.3.4 Door and Signal Timing
EXCEPTIONS: 1....