Accessible Routes—An accessible route is a continuous, unobstructed path that connects all accessible elements and spaces of a building or facility....
Search Results "Shower Clear Floor Space"
Commonly Searched Documents
-
Key Differences Between Routes
- Activar JL Industries ORBIT SERIES - LOW PROFILE CABINET
-
1010.1.7 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B.707.7.1.1 Vertically mounted display screen
mounted vertically or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
- Magnuson Group CUBIC SOISTES Magazine Stand
-
Element-by-Element Safe Harbor
The 1991 Standards require one van accessible space for every eight accessible spaces. The 2010 Standards require one van accessible space for every six accessible spaces....
- American Standard Green Tea Deck-Mount Tub Filler
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
1009.5.1 Transfer Platform
Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width. Figure 1009.5.1 Size of Transfer Platform...
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
Attachment B – Code References
Creating designated accessible parking spaces. Removing high-pile, low-density carpeting. 5....
-
General: ADA Standard Section 211.1
Section 211.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for drinking fountains.
-
Counter: ADA Standard Section 904.3.2
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
11B-203.13 Raised boxing or wrestling rings
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.3.2 Touch screen call console arrangement
The accessibility function button shall be located at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
- Bradley 2 Station Express Deck Lavatory System EXD-2N
-
5. Ground Level PV Systems
Ground Level PV Systems Ground level PV systems will have components other than vertical supports installed less than 80 inches above the ground or floor surface....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
5. Discussion of Proposed Standards
The Access Board is committed to writing standards that are clear, concise, and easy to understand so that persons who use the standards know what is required. Question 4....
-
Coin Slot Height
Is it mounted with the coin slot no higher than 54" above the floor, and one pay phone on that floor with the highest operable element no higher than 48" above the floor?...