In new construction, platform lifts can be used to provide an accessible route to these areas only: wheelchair spaces, performance areas, and speakers’ platforms incidental...
Search Results "Lavatory Clear Floor Space"
-
Where Platform Lifts are Permitted [§206.7]
- AD Systems’ Exam Room Doors
-
11B-603.6 Guest room toilet and bathing rooms
shall provide all toilet and bathing fixtures in a location that allows a person using a wheelchair measuring 30 inches by 48 inches (762 mm by 1219 mm) to touch the wheelchair to any lavatory...
-
Lateral grab bar use
Table 12 summarizes the average clear space required for our subjects to position their WMD to perform a transfer in each protocol in terms of width, depth, and angle of approach (Figure...
-
Protruding Objects and Trails
Protruding objects are defined as constructed features such as signs that extend into the clear width area of a trail, resting interval, or passing space between 27 inches (685 millimeters...
-
1016.6 Openings
Spaces between the boards in a boardwalk and drainage grates are examples of openings. ...
-
1016.6 Openings
Spaces between the boards in a boardwalk and drainage grates are examples of openings....
-
Camping Units
The minimum size of a camp living area is determined by the type and number of constructed features provided and the required clear space around each feature....
-
ABA CHAPTER 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
[See subsections ...]
-
4. ACCESSIBLE ELEMENTS AND SPACES: SCOPE AND TECHNICAL REQUIREMENTS
[See subsections ...]
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors. The width of the level area at the exterior side...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors. The width of the level area at the exterior side...
- Clarity XLC2 Amplified Cordless Phone
- Clarity XLC3.4 DECT 6.0 Extra Loud Big Button Speakerphone with Talking Caller ID and ClarityLogic™
-
E.
In some of Cinemark's auditoria with 300 seats or less, persons who use wheelchairs cannot access the seating on risers as the wheelchair spaces available to them are located on the traditional...
-
206.2.3 Multi-Story Buildings and Facilities
Spaces and elements located on a level not required to be served by an accessible route must fully comply with this document....
-
4.1.2(7)
(b) Within a building or facility, at least one door at each accessible space shall comply with 4.13....
-
11B-603.6 Guest room toilet and bathing rooms
shall provide all toilet and bathing fixtures in a location that allows a person using a wheelchair measuring 30 inches by 48 inches (762 mm by 1219 mm) to touch the wheelchair to any lavatory...
-
807.2.4 Toilet and Bathing Facilities
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610....
-
11B-603.6 Guest room toilet and bathing rooms
shall provide all toilet and bathing fixtures in a location that allows a person using a wheelchair measuring 30 inches by 48 inches (762 mm by 1219 mm) to touch the wheelchair to any lavatory...
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
- Rebuilding Together Of the Triangle - Raleigh, NC
-
Signs [ADA Standards §216, §703]
Tactile signs must include compliant raised characters and braille characters and be located at doors 48” to 60” above the floor or ground (§703.2)....