Specifically, the Department requested comment on the effectiveness of: annual surveys to assess the number of projects developed with accessible buildings; recordkeeping requirements; and...
Search Results "Fire-Building Surface"
-
Enforcement Mechanisms
-
CHAPTER 11A HOUSING ACCESSIBILITY
ETA Editor's Note Sections from California Building Code Chapter 11A not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted....
-
11B-211.2 Minimum number
The 2016 California Plumbing Code (CPC), Table 4-1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
CHAPTER 11A HOUSING ACCESSIBILITY
ETA Editor's Note Sections from California Building Code Chapter 11A that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
11B-211.2 Minimum number
The 2019 California Plumbing Code (CPC), Table 4-1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
101.1 General
This document contains scoping and technical requirements for accessibility to sites, facilities, buildings, and elements by individuals with disabilities....
-
11B-806.2.4.1 Vanity counter top space
. ◼ ETA Editor's Note: From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle: "Addition of the word “...
-
11B-244.1 General
Religious facilities are exempt from federal ADA requirements, however no exception is provided for these types of facilities under the California Building Code (CBC) due to pre-existing...
-
11B-227.3 Counters
Where counters are dispersed throughout the building or facility, counters complying with Section 11B-904.4 also shall be dispersed. Advisory 11B-227.3 Counters....
-
ASSEMBLY AREA
[DSA-AC] A building or facility, or portion thereof, used for the purpose of entertainment, educational or civic gatherings, or similar purposes....
-
1009.4.2 Area of refuge
Areas of refuge are not required in buildings and facilities equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2....
-
11B-244.1 General
Religious facilities are exempt from federal ADA requirements, however no exception is provided for these types of facilities under the California Building Code (CBC) due to pre-existing...
-
ASSEMBLY AREA
[DSA-AC] A building or facility, or portion thereof, used for the purpose of entertainment, educational or civic gatherings, or similar purposes....
-
11B-227.3 Counters
Where counters are dispersed throughout the building or facility, counters complying with Section 11B-904.4 also shall be dispersed. Advisory 11B-227.3 Counters....
-
1009.3.3 Area of Refuge
Areas of refuge are not required at stairways in buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1....
-
406.2.2 Clear height
Exception: A lower clear height is permitted for a parking tier in mechanical-access open parking where approved by the building official. Advisory 406.2.2 Clear height....
- Stanley QDC 100 Series Grade 1 Extra Heavy-Duty Door Closers
- Allegion Schlage S200-Series Mechanical Locks with Tubular Interconnect
- Locus Labs Inc. LocusMaps SDK
-
Service Animals
Service Animals: Ensure that all participants and the meeting site staff understand that the ADA requires that service animals are allowed to enter the building and remain with their...
-
Is Prior Knowledge of the Circulation Path Location(s) Necessary?
Once properly notified by appropriate visual notification devices of an alarm or special instructions, people who are deaf or hard of hearing can use any standard means of egress from the building...
-
Sec. 469.003(b)
(b) To the extent there is not a conflict with federal law and it is not beyond the state's regulatory power, the standards adopted under this chapter apply to a building or facility constructed...