If gratings are located in walking surfaces, then they shall have spaces no greater than 1/2 in (13 mm) wide in one direction (see Fig. 8(g))....
Search Results "Character Spacing (VMS)"
-
4.5.4 GRATINGS
-
General [§202.1]
The extent of application is largely determined by a project’s scope of work as the standards apply to those elements or spaces that are altered or added....
-
III- 7.4400 Signage
The international symbol of accessibility must be used to indicate accessible parking spaces; accessible passenger loading zones; and accessible entrances and toilet facilities, if all are...
-
Access to Approach, Enter, and Exit Work Areas
Access for “approach, entry, and exit” requires a connecting accessible route to the work area and a compliant entrance, including entry doors or gates, plus wheelchair space in the work...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground space...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground space...
-
Tent Pads and Tent Platforms
Provide a minimum 48-inch (1,220-millimeter) clear floor or ground space on all sides of tents on tent pads and platforms that are required to be accessible....
- The UpScale Medical Exam Table
- Stable and rock solid. See for yourself!
-
11B-101.2 Reserved.
These measures include, for example, installing an entrance ramp, widening entrances, and providing accessible parking spaces. 2) Second, a public accommodation should take measures...
-
11B-101.2 Reserved.
These measures include, for example, installing an entrance ramp, widening entrances, and providing accessible parking spaces. 2) Second, a public accommodation should take measures...
- Society for the Blind
- Neurofibromatosis Network
-
Expert Report of James L.E. Terry, Evan Terry Associates, LLC (August 9, 2018)
Alexander Deussen Park Senior Center, 12303 Sonnier Street, Houston, TX Parking: The surface slope in the designated accessible parking space and access aisle is not level in all...
-
3.15
3.15 Nothing in this Consent Order shall limit the placement of any additional wheelchair spaces required by state or local codes beyond those mandated under the ADA Standard 4.33.3 and...
-
Technical Requirements
The Board agrees and has relocated these provisions to a new technical section in Chapter 8 (Special Rooms, Spaces, and Elements) at section 808 that is specific to courtrooms....
-
R215 Passenger Loading Zones (Section-by-Section Analysis)
Loading Zones (Section-by-Section Analysis) Where passenger loading zones are provided, at least one passenger loading zone for each 30 meters (100 feet) of continuous loading zone space...
-
Direct Connections
This is not intended to increase the number of entrances planned where a building entrance serves more than one of these spaces....
-
§ 38.113(a)(1)
(1) At least one doorway, on each side of the car from which passengers board, of each car required to be accessible by §38.111(a) and where the spaces required by §38.111(d) of this part...
-
When is accessibility required for a live work conversion project?
new JLWQ’s will be designated as R-2 Use for purposes of applying the CBC The new JLWQ’s will be for lease only The tenants will have no employees The tenants will not use the JLWQ space...
-
Elevator requirement to new dining area on the mezzanine of an existing facility
The conversion of bank spaces in a pre-ADA building into a restaurant is clearly an alteration affecting the usability of primary function areas so normally the path of travel obligation...
-
11B-806.2 Guest rooms with mobility features
The requirements in 806.2 do not include requirements that are common to all accessible spaces....
-
1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...