Signs providing direction to or information about interior spaces and facilities are required to comply....
Search Results "Serving Space"
Commonly Searched Documents
-
Information and Directional Signs
-
Question 19
Are the entrances to accessible public restrooms and fitting rooms free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the...
-
Step-by-Step Guide
The guide has been arranged in four steps and provides spaces to fill in numeric values of play components for evaluating a specific play area design....
-
902.4 Dining Surfaces and Work Surfaces for Children's Use
EXCEPTION: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with 902.4 where a clear floor or ground space complying...
-
902.4 Dining Surfaces and Work Surfaces for Children's Use
EXCEPTION: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with 902.4 where a clear floor or ground space complying...
-
D6
If an entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the swing of a hinged door?...
-
J6
Is the bottom of the apron of the fountain 27 inches above the floor so that it provides the space needed for a person who uses a wheelchair to pull up under it but is not a hazard to people...
-
1132A.4, Item 2
., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½ inch (12.7 mm) of change in height between floor...
-
Forward Approach
Clear floor space must be provided to the face of the unit since the seated forward reach does not extend much beyond the toes....
-
4.7.3 Slope
The slope of the clear floor or ground spaces required by section 4.0 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
Side Reach [§308.3]
The maximum reach depth for this range is 10” measured from the available clear floor space....
-
1132A.4, Item 2
., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½ inch (12.7 mm) of change in height between floor...
-
§ 35.138(d)(3) Sales limited to less than four tickets
sales of tickets to fewer than four seats per patron, then the public entity is only obligated to offer as many seats to patrons with disabilities, including the ticket for the wheelchair space...
-
Co-sharing of Accessible Parking access Aisles by adjacent elevator door allowed?
Given: multistory parking structure circa 1980 with limited head height for vans Issue: Can an elevator door open to and co-share/use an access aisle for an accessible parking space?...
-
Expert Report of James L.E. Terry, Evan Terry Associates, LLC (August 9, 2018)
Alexander Deussen Park Senior Center, 12303 Sonnier Street, Houston, TX Parking: The surface slope in the designated accessible parking space and access aisle is not level in all...
-
Accessible Route
For example, where the total length of a gangway or series of gangways serving as an accessible route is 80 feet or more an exception permits the slope on gangways to exceed the maximum...
-
ADAAG
The Access Board develops the requirements as "guidelines" to serve as a basis for standards developed by the Department of Justice (DOJ) and the Department of Transportation (DOT)....
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground space...
-
2.2 Entrances
Once inside the building, is the accessible route to all public spaces at least 36 inches wide?...
-
4.5.4 Gratings
If gratings are located in walking surfaces, then they shall have spaces no greater than 1/2 in (13 mm) wide in one direction (see Fig. 8(g))....
-
4.28.2* Audible Alarms
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 dbA or exceeds any maximum sound level...
-
4.28.2* AUDIBLE ALARMS
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 decibels or exceeds any maximum sound level...
-
4.5.4 GRATINGS
If gratings are located in walking surfaces, then they shall have spaces no greater than 1/2 in (13 mm) wide in one direction (see Fig. 8(g))....
-
General [§202.1]
The extent of application is largely determined by a project’s scope of work as the standards apply to those elements or spaces that are altered or added....