of the types of residential dwelling units provided, one-story residential dwelling units shall be permitted as a substitute for multi-story residential dwelling units where equivalent spaces...
Search Results "Occupiable Space"
-
11B-233.3.5 Dispersion
-
11B-604.7 Dispensers and disposal units
Combination accessory units are not permitted to encroach into the space required by Section 11B-609.3. [2010 ADA Standards] 604.7 Dispensers....
-
11B-411.2.1.2.3 Accessibility function button
The dots shall be spaced ¼ inch (6.4 mm), measured center to center, in the form of an equilateral triangle with a vertex pointing up....
-
11B-213.3.1 Toilet compartments
A toilet compartment is a partitioned space that is located within a toilet room, and that normally contains no more than one water closet....
-
11B-706.1 General
On the other hand, an infrared system is typically a better choice than an FM system where confidential transmission is important because it will be contained within a given space....
-
[2010 ADAS] 105.2.4 ICC/IBC
At least one accessible means of egress is required for every accessible space and at least two accessible means of egress are required where more than one means of egress is required....
-
Sections 5 Through 9 (Preamble, Section-by-Section Analysis)
In a newly constructed or altered facility with less than 5,000 square feet of selling space, at least one of each type of check-out aisle must be accessible....
-
F105.2.4 ICC/IBC
At least one accessible means of egress is required for every accessible space and at least two accessible means of egress are required where more than one means of egress is required....
-
105.2.4 ICC/IBC
At least one accessible means of egress is required for every accessible space and at least two accessible means of egress are required where more than one means of egress is required....
-
For People with Disabilities, Which Circulation Paths Are Usable, Available, and Closest?
The requirements include but are not limited to the type, size, spacing, and color of letters for visual characters and the type, size, location, character height, stroke width, and line...
-
Conclusions
No studies or measurement of transfers were recorded nor did we collect information on the space needs of other tasks on exam tables like repositioning the body for exams....
-
NAADAC Webinar Series: "ADA: The Next Generation" - Virtual and At-Home Training
beyond, Safe Harbors (10/27/10), Run time: 1.5 hrs ADA Standards – Admin provisions, Accessible Routes, Building Blocks (11/3/10), Run time: 1.5 hrs ADA Standards – Common Space...
-
SHELTERS + SERVICE CENTERS
Use the online Share Your Space Survey, nyc.gov/shareyourspacesurvey, or call 311 to register your local community space....
-
105.2.4 ICC/IBC
At least one accessible means of egress is required for every accessible space and at least two accessible means of egress are required where more than one means of egress is required....
-
Workshops
“Space Requirements for Wheeled Mobility” workshop was held in 2003. It was attended by 70 experts from the U.S. and abroad....
-
Sections 5 Through 9 (Section-By-Section Analysis and Response to Comments)
In a newly constructed or altered facility with less than 5,000 square feet of selling space, at least one of each type of check-out aisle must be accessible....
-
Circulation Paths
Protruding objects shall not reduce the clear width of an accessible route or maneuvering space (see Fig.8(e)). 4.4.2 Head Room....
-
Wading pools. (Section-by-Section Analysis)
Several commenters felt that the required clear deck space surrounding a pool provided sufficient space for a sloped entry during alterations....
-
11B-706.1 General
On the other hand, an infrared system is typically a better choice than an FM system where confidential transmission is important because it will be contained within a given space....
-
11B-205.1 General
Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply with Section 11B-309. Exceptions: 1....
-
ICC/IBC
At least one accessible means of egress is required for every accessible space and at least two accessible means of egress are required where more than one means of egress is required....
-
Raised Letter Braille requirement - Exterior
Or is the suite number now identifying a permanent room and space, requiring the RLB?...
-
Re: Section 307 Protruding Objects
The more blatant inconsistency is the lavatory, which is required to be 17" deep minimum due to the required forward approach clear floor/knee and toe space, and must provide knee clearance...
-
Can parking signage height be considered a "safe harbor"?
2010 Standard 502.6 says 60" min. to parking sign bottom. 1991 Standard 4.6.4 said parking signs need to be high enough "so they cannot be obscured by a vehicle parked in the space."...