Provide an 18" distance between the side wall and the toilet centerline of the men's toilet room in the Banquet area. See Standards § 4.16.2....
Search Results "Healthcare Provider"
Commonly Searched Documents
-
d. i.
-
611.2 Clear Floor Space
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
F242.3 Wading Pools
At least one accessible means of entry shall be provided for wading pools. Accessible means of entry shall comply with sloped entries complying with 1009.3....
-
F238.2.3 Weather Shelters
Where provided, weather shelters shall be designed and constructed so that a golf car can enter and exit the weather shelter and shall comply with 1006.4....
-
F245.4.1 Routes Within Picnic Units with Mobility Features
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within picnic units with mobility features....
-
F235.3 Boarding Piers at Boat Launch Ramps
Where boarding piers are provided at boat launch ramps, at least 5 percent, but no fewer than one, of the boarding piers shall comply with 1003.3.2....
-
F206.7.3 Incidental Spaces
Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum....
-
Circulation Path
An exterior or interior way of passage provided for pedestrian travel, including but not limited to, walks, hallways, courtyards, elevators, platform lifts, ramps, stairways, and landings...
-
§ 1194.23(e)
(e) Where provided, caller identification and similar telecommunications functions shall also be available for users of TTYs, and for users who cannot see displays....
-
Doors
Main Lobby restroom: provide a restroom vestibule door with at least 18" of maneuvering clearance on the latch side of the door. See Standards § 4.13.6....
-
804.6.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
-
407.4.9 Emergency Communication
Tactile symbols and characters shall be provided adjacent to the device and shall comply with 703.2....
-
704.2.1.1 Parallel Approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (255 mm) maximum....
-
805.1 General
Medical care facility and long-term care facility patient or resident sleeping rooms required to provide mobility features shall comply with 805....
-
206.7.3 Incidental Spaces
Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum....
-
235.3 Boarding Piers at Boat Launch Ramps
Where boarding piers are provided at boat launch ramps, at least 5 percent, but no fewer than one, of the boarding piers shall comply with 1003.3.2....
-
238.2.3 Weather Shelters
Where provided, weather shelters shall be designed and constructed so that a golf car can enter and exit the weather shelter and shall comply with 1006.4....
-
242.3 Wading Pools
At least one accessible means of entry shall be provided for wading pools. Accessible means of entry shall comply with sloped entries complying with 1009.3....
-
§27.71(k)(8) Braille instructions.
Braille instructions for initiating the speech mode must be provided. Braille must comply with section 703.3 of the 2010 ADA Standards....
-
11B-812 Electric vehicle charging stations
SECTION TITLE NOTES 11B-812 Electric vehicle charging stations Provides new section with technical...
-
Adjusted Construction Cost
DEFINITION NOTES Adjusted Construction Cost New and explicit definition to provide specific costs included in the adjusted...
-
§ 27.71(k)(8) Braille instructions
Braille instructions for initiating the speech mode must be provided. Braille must comply with section 703.3 of the 2010 ADA Standards....
-
§ 382.57(c)(8) Braille instructions
Braille instructions for initiating the speech mode must be provided. Braille must comply with section 703.3 of the 2010 ADA Standards....
-
503.3 Alternative User Interfaces
Where an application provides an alternative user interface that functions as assistive technology, the application shall use platform and other industry standard accessibility services....