facilities, including, but not limited to, the provisions in sections 233 and 809. 1) In sleeping rooms with more than 25 beds covered by this part, a minimum of 5% of the beds shall have clear...
Search Results "Lavatory Clear Floor Space"
-
11B-233.3.6 Graduate student and faculty housing at a place of education
-
Executive Summary
high and how low wheeled mobility device users can transfer to a platform above and below their mobility device seat, how high and how low users can transfer between two platform steps, clear...
-
4. My pool already existed before the effective date of the new rule. What am I required to do to provide pool access to customers with mobility disabilities?
The 2010 Standards for pool lifts require lifts to be fixed and to meet additional requirements for location, size of the seat, lifting capacity, and clear floor space....
-
Site Constraints
This is intended to cover altered facilities where limited space or other constraints preclude construction of a complying ramp....
-
306.3.1 General
Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3....
-
502.6 Identification
Parking space identification signs shall include the International Symbol of Accessibility complying with 703.7.2.1....
-
1007.1 Accessible means of egress required
Accessible spaces shall be provided with not less than one accessible means of egress....
-
ETA Public Telephone Summary Chart and Survey Instructions
. [4.1.3(17)(a)] b. 1 per floor, when 1 bank is provided on this floor [4.1.3(17)(a)] c. 1 per bank, when 2 or more banks are provided on this floor....
-
Provisions for Adults [2.1]
These optional specifications address drinking fountains, water closets, toilet stalls, lavatories, sinks, and fixed or built-in seating and tables....
-
1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
R405.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear space, the knee clearance shall be 280 mm (11 in) deep minimum at 230 mm (9 in) above the finish surface, and 205 mm...
-
1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
Parallel Curb Ramps (R304.3) (Section-by-Section Analysis)
A turning space must be provided at the bottom of parallel curb ramps....
-
8 [§§ 4.3.3; 4.3.7]
8 [§§ 4.3.3; 4.3.7] Curb ramps should have at least 36 inches of clear space at the “top” of the ramp, which can be seen in the illustration to the right [below]....
-
Platform Size and Surface
Platform Size and Surface To be part of an accessible route, lift platforms must provide the amount of clear space required for wheelchairs in ADAAG 4.2.4....
-
Findings
However, the design may not have allocated for the 30 x 48 inch clear floor space to transfer at the swing or the required 60 inch diameter turning space adjacent to the swing. ...
-
Dimensions: ADA Standard Section 810.2.2
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
1.17 Unobstructed view
is not blocked or interfered with by any seats, railings, or other objects and is configured to have visual clearance over average height patrons seated one row ahead of the wheelchair spaces...
-
7.4.9 Trail Facilities
When the surface of the required clear ground space for trail facilities is not paved or is not elevated above the natural ground, slopes not steeper than 1:20 (5 percent) shall be permitted...
-
1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
805.4 Toilet and Bathing Rooms
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610....
-
306.2.4 Additional Clearance
Space extending greater than 6 inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the finish floor or ground shall not be considered toe clearance....
-
DIVISION 8: SPECIAL ROOMS, SPACES AND ELEMENTS
[See subsections ...]