Patient bedrooms and resident sleeping rooms required to provide mobility features shall comply with Section 11B-805.2. ETA Editor's Note According to the Office of...
Search Results "Medical Restriction"
Commonly Searched Documents
-
11B-805.2 Patient bedrooms and resident sleeping rooms
-
11B-805.4.2 Equipment
Clear space complying with Section 11B-305.2 shall be provided as required for specific equipment.
-
In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?
The medical care provider must be able to provide its services in an accessible manner to individuals with disabilities. In order to do so, accessible equipment is usually necessary....
- Defining and Delivering Disability-Competent Care - The Care Coordination Relationship
-
232.1 General
Buildings, facilities, or portions thereof, in which people are detained for penal or correction purposes, or in which the liberty of the inmates is restricted for security reasons shall...
-
11B-223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient bedrooms or resident sleeping rooms shall be provided...
-
11B-223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient bedrooms or resident sleeping rooms shall be provided...
-
I have an accessible exam table, but if it is in use when a patient with a disability comes in for an appointment, is it OK to make the patient wait for the room to open up, or else use an exam table that is not accessible?
This way, the medical provider can be prepared to provide the assistance and staff needed....
-
11B-223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient bedrooms or resident sleeping rooms shall be provided...
-
PART 3: ACCESSIBLE EXAMINATION ROOMS
An accessible examination room has features that make it possible for patients with mobility disabilities, including those who use wheelchairs, to receive appropriate medical care....
-
SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND THE VILLAGE OF RUIDOSO, NEW MEXICO DJ # 205-49-24
SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND THE VILLAGE OF RUIDOSO, NEW MEXICO DJ # 205-49-24 The parties to this Settlement Agreement are the United...
-
SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND THE CITY OF VERO BEACH, FLORIDA DJ 205-18-16
[See subsections ...]
-
223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient or resident sleeping rooms shall be provided in accordance...
-
2. Standing Supports
received two comments, one of which addressed standing supports on mammography equipment (discussed above in Section IV.D.1 (Significant Changes – Standing Supports)) and one commenter (medical...
-
3.2 Getting on the Table
The Patient’s Perspective on Access to Medical Equipment. In J. Winters and M. Story (Ed.), Medical Instrumentation: Accessibility and Usability Considerations (pp. 3-14)....
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
-
M303.2.4.1 Breast Platforms
Wheelchair spaces beneath breast platforms shall comply with M303.2.4.1.
-
M303.2.4.1.1 Depth
Wheelchair spaces shall include knee and toe clearance 25 inches (635 mm) deep minimum and 28 inches (710 mm) deep maximum.
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair...
-
11B-223.2 Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities
Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities shall comply with Section 11B-223.2. All public use and common use areas shall be...
-
a. Knee and Toe Clearance
The proposed rule recommended a knee and toe clearance depth for breast platforms of 25 inches. There were no comments received on this requirement. The MDE Advisory Committee...
-
M302 Diagnostic Equipment used by Patients in a Seated Position (Section-by-Section Analysis)
M302 in the final rule establishes the technical criteria for diagnostic equipment used by patients in a seated position such as examination chairs.
-
5.8.2.4 Unobstructed Floor Space Recommendation
5.8.2.4 Unobstructed Floor Space Recommendation The Committee recommends the unobstructed floor space in front of the base support be a minimum of 17 inches deep. Rationale for...
-
5.8.2 Knee and Toe Clearance Under Breast Platform
5.8.2 Knee and Toe Clearance Under Breast Platform. The overall knee and toe space should be increased to a minimum of 28 inches deep, from the initially proposed 25 inch absolute...