smoke-rated ICU/CCU door system offered in a telescoping design, this Horton door technology introduces a wider range of architectural options and greatly enhances accessibility for moving patient...
Search Results "Ceiling Mounted Patient Lift"
- Horton Automatics Profiler® Smoke-Rated Telescoping ICU/CCU Sliding Door
-
§ 38.83(b)(11) Boarding direction
The lift shall permit both inboard and outboard facing of wheelchairs and mobility aids....
-
F223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient or resident sleeping rooms shall be provided in accordance...
-
§ 38.23(b)(11) Boarding direction
The lift shall permit both inboard and outboard facing of wheelchair and mobility aid users....
-
§ 38.125(b)(2)(iii) Exception
The brake or propulsion system interlocks requirement does not apply to platform mounted or portable lifts provided that a mechanical, electrical or other system operates to ensure that...
- Stanley Access Technologies Dura-Care 7000 Manual Door System
-
M301.3 Transfer Supports
Height: Located no less than 6 inches (150 mm) and no more than 19 inches (482 mm) above the patient support surface Horizontal Distance from Transfer Surface: No more than 3 inches (...
-
General: ADA Standard Section 307.1
Section 307.1 of the ADA Standards covers information in the current ADA Standards for protruding objects.
-
Protruding Objects: ADA Standard Section 204
Section 204 covers the scoping requirements of general exceptions for protruding objects in the most current ADA Standards
-
Protruding Objects: ADA Standard Section 307
Section 307 covers the current ADA Standards for protruding objects.
-
11B-204 Protruding objects
[See subsections ...]
-
11B-307.1 General
Protruding objects shall comply with Section 11B-307.
-
11B-307 Protruding objects
[See subsections ...]
-
11B-307 Protruding objects
[See subsections ...]
-
11B-307.1 General
Protruding objects shall comply with Section 11B-307.
-
11B-204 Protruding objects
[See subsections ...]
-
Clear Deck Space
Clear Deck Space Clear deck space must be provided to enable a person to get close enough to the pool lift seat to easily transfer from a wheelchair or mobility device....
-
M301.1 General (Section-by-Section Analysis)
The MDE NPRM proposed that all diagnostic equipment used by patients in a supine, prone, or side-lying position must comply with the technical requirements of proposed section M301....
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
M301.2.2, M302.2.2 Transfer Size
M301.2.2, M302.2.2 Transfer Size Proposed requirement: 30" wide minimum and 15" deep minimum • Sub-Committee Recommendation: 28" wide minimum and 17" deep minimum. This...
-
Maneuvering Clearances: ADA Standard Section 404.2.4
Section 404.2.4 covers the current ADA Standards for maneuvering clearances at doors, doorways, and gates.
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
1009.2.6 Footrests and Armrests
EXCEPTION: Footrests shall not be required on pool lifts provided in spas....