Analysis of the footrest clearance height, abdomen-castor depth and abdomen-footrest depth suggests a flange of depth 10-10.7 in. and thickness 1-1.2 in. maximum....
Search Results "Transfer Surface Height"
-
Conclusions
-
Elevators
4.10.6); Door and signal timing for hall calls (§ 4.10.7); Door delay for car calls (§ 4.10.8); Illumination levels (§ 4.10.11); Car control size, mounting height...
-
11B-607.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis)
In addition, this proposed section also contains subsections, as discussed below, establishing maximum heights for operable parts with obstructed forward reaches, as well as dimensions for...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Forward Approach Scooter
These data depict the reaching abilities of scooter users represented as the percentage of users expected to reach to a target location in the forward reach direction for a given (a) height...
-
11B-407.2.1.3 Clear floor or ground space
The height of the clear floor or ground space is considered to be a volume from the floor to 80 inches (2030 mm) above the floor....
-
11B-407.2.1.3 Clear floor or ground space
The height of the clear floor or ground space is considered to be a volume from the floor to 80 inches (2030 mm) above the floor....
-
11B-607.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
8.5 Updating Standards in the Future
As noted above, the general population is increasingly overweight and obese; if population heights and weights change significantly, this might alter dimensions required for equipment accessibility...
-
11B-608.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
11B-608.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
Guidelines for Requirement 5
The final Guidelines clarify that to be in an accessible location within the meaning of the Act, the maximum height for an environmental control, for which reach is over an obstruction,...
-
1134A.6, Item 2
The floor surfaces shall be of Carborundum or grit-faced tile or of material providing equivalent slip resistance....
-
T405.3 Visual Contrast
The stripe shall be 1 inch (25 mm) wide minimum and shall contrast visually with the rest of the step tread or circulation path surface either light-on-dark or dark-on-light....
-
6.10 Openings
Openings in the surface of beach access routes and their related resting intervals may be up to 1/2 inch (13 millimeters) wide....
-
1134A.6, Item 2
The floor surfaces shall be of Carborundum or grit-faced tile or of material providing equivalent slip resistance....
-
11B-809.10.6.2 Slope
The floor surfaces shall be of Carborundum, grit-faced tile or of material providing equivalent slip resistance....
-
Toilet Buildings and Pit Toilets
If the pit toilet has a riser and toilet seat, ensure that the total height of that seat and the riser it rests on is 17 to 19 inches (430 to 485 millimeters) above the ground or floor....
- PEMKO 5 1/8" Thermal Barrier Threshold No. 252X3-FG
- Kompan, Inc. M590 - Mermaid's Fountain
- Pemko 252X2_FG Thermal Barrier Threshold
- PEMKO 6 1/8" Thermal Barrier Threshold No. 273X3-FG
- Georgia-Pacific enMotion® Recessed Automated Touchless Towel Dispenser
- PEMKO 8 1/8" Thermal Barrier Threshold No. 254X4-FG