Section 223.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for medical care and long-term care facilities.
Search Results "Limited Access Space"
-
General: ADA Standard Section 223.1
-
604.2 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible...
-
Common Problems with Websites
are accessible....
-
Base Support [No specific provision—affects M303.2.4]
It does obstruct the floor space in front of the gantry and, thus, may limit how close a wheelchair can get to the equipment....
-
Running Slope [1016.7.1]
Table 3—Maximum Running Slope and Segment Length Running Slope of Segment of Outdoor Recreation Access Route Maximum Length of Segment Steeper Than But Not...
-
4.3.7 Slope
An accessible route with a running slope greater than 1:20 is a ramp and shall comply with 4.8. Nowhere shall the cross slope of an accessible route exceed 1:50....
-
4.3.7 SLOPE
An accessible route with a running slope greater than 1:20 is a ramp and shall comply with 4.8. Nowhere shall the cross slope of an accessible route exceed 1:50....
-
Section H: Lifts
(§410.1) H3 Is there 30" by 48" of clear floor space within the lift?...
-
6.2.3 Bathing and Toilet Facilities Constructed at Beaches
Where bathing and toilet facilities are constructed at developed beach sites and pedestrian access points to the beach are provided near the bathing and toilet facilities, beach access routes...
- Williams Sound FM ADA KIT 37 - FM ADA Compliance Kit
- Seton Men's Rest Room ADA Braille Sign with ISA 44988
- Seton Women's Rest Room ADA Braille Sign with ISA 44985
- Seton Unisex Rest Room ADA Braille Sign with ISA 44982
-
2. Standing Supports
The Access Board concurs with most of the MDE Advisory Committee’s recommendations; however, although the Committee’s recommendations pertained to diagnostic equipment with wheelchair spaces...
-
Areas of Rescue Assistance [4.1.3(9), 4.3.11]
Areas of rescue assistance are fire-rated spaces where people unable to use stairs can await evacuation assistance from emergency personnel....
-
604.2 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible...
-
R208.1 Where Required
Detectable warning surfaces complying with R305 shall be provided at the following locations on pedestrian access routes and at transit stops: 1....
-
Swimming Pools, Wading Pools & Spas
Word Fillable Form (2.8MB) Word Non-Fillable Form (2.6MB) PDF Non-Fillable Form (1.0MB)
-
Alterations and Water Closet Clearances in Single-User Toilet Rooms With In-Swinging Doors (Section-by-Section Analysis)
The 1991 Standards do not allow an in-swinging door in a toilet or bathing room to overlap the required clear floor space at any accessible fixture....
-
4.7.1 General
All utilities required to be accessible shall be connected to an ORAR complying with section 2.0. Exception....
-
K) Temporary Events
The Standards can provide guidance to help event planners place temporary accessible parking spaces in appropriate locations, provide an accessible route throughout the site, and provide...
-
6.2.4 Beach Nourishment
Beach access routes shall be provided where a beach nourishment project is undertaken....
-
B. Survey and Review of Polling Place Locations
The City shall review each newly proposed polling place location to determine whether it is accessible to persons with disabilities or could be made accessible on Election Day through the...
-
J. PHYSICAL CHANGES TO EMERGENCY SHELTERS