(2) Alterations to an Area Containing a Primary Function: In addition to the requirements of 4.1.6(1), an alteration that affects or could affect the usability of or access to an area containing...
Search Results "Clear Floor Area"
Commonly Searched Documents
-
4.1.6(2)
-
[ADA Titles II & III] Primary Function
Areas that contain a primary function include, but are not limited to, _|ADA Title III: the customer services lobby of a bank, |_ the dining area of a cafeteria, the meeting rooms in a conference...
-
[ADA Titles II & III] Primary Function
Areas that contain a primary function include, but are not limited to, _|ADA Title III: the customer services lobby of a bank, |_ the dining area of a cafeteria, the meeting rooms in a conference...
-
Professional Office of a Health Care Provider
The facility housing the “professional office of a health care provider” only includes floor levels housing at least one health care provider, or any floor level designed or intended for...
-
11B-306.3.1 General
Space under an element between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground shall be considered knee clearance and shall comply with Section 11B-306.3....
-
4(3)
unit that is served by the building elevator (a) is the primary entry to the unit; (b) complies with Requirements 2 through 7 with respect to the rooms located on the entry/accessible floor...
-
Do basements count in determining a facility’s story count?
As defined in the Standards, a “story” pertains to those portions of buildings “designed for human occupancy included between the upper surface of a floor and upper surface of the floor...
-
11B-306.3.1 General
Space under an element between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground shall be considered knee clearance and shall comply with Section 11B-306.3. ...
-
11B-306.3.1 General
Space under an element between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground shall be considered knee clearance and shall comply with Section 11B-306.3....
-
Scoping Requirements [F244.5, F245.4, F246.4, and F247.3.2]
or common use areas....
-
11B-308.1.1 Electrical switches
Controls and switches intended to be used by the occupant of a room or area to control lighting and receptacle outlets, appliances or cooling, heating and ventilating equipment, shall comply...
-
Sec.36.403(e)(1)
(1) A "path of travel'' includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited, and which connects the altered...
-
§ 36.403(e)(1)
(1) A "path of travel" includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited, and which connects the altered...
-
§ 35.151(b)(4)(ii)
(ii) A path of travel includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited, and which connects the altered...
-
Accessible Spaces [9.2.2(6)]
Accessible Spaces [9.2.2(6)] Where provided in accessible units, sleeping rooms, or suites, the following spaces are required to be accessible and be on an accessible route: living areas...
-
§ 35.151(b)(4)(ii)
(ii) A “path of travel” includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited, and which connects the altered...
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
11B-604.8.2.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area. [2010 ADA Standards] 604.8.2.2 Doors....
- The Ohio State University ADA Coordinator's Office
-
11B-608.5.3 Alternate roll-in type shower compartments
The controls, faucets, and shower spray units shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor....
-
BHMA
Builders Hardware Manufacturers’ Association 355 Lexington Avenue, 15th Floor New York, NY 10017 A 156.10-2017: Power Operated Pedestrian Doors 1010.3.2, 11B-404.2.9, 11B-404.3...
-
Service
Keep lowered check-in counter clear. Where only high counters are available (older lodging facilities) train staff to come out from behind counter and provide a clipboard....
-
§ 35.151(b)(4)(i)(A)
(A) Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, and corridors are not areas containing a primary function. ...