Thresholds at doorways shall not exceed ¾ inch (19.1 mm) in height above the finished floor or landing for sliding doors serving dwelling units or ½ inch (12.7 mm) above the finished floor...
Search Results "Clear Floor Area"
-
1010.1.6 Thresholds
-
1010.1.6 Thresholds
Thresholds at doorways shall not exceed ¾ inch (19.1 mm) in height above the finished floor or landing for sliding doors serving dwelling units or ½ inch (12.7 mm) above the finished floor...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
Existing Site Constraints: ADA Standard Section 206.7.5
Section 206.5.1 covers scoping requirements in the most current ADA Standards for the use of platform lifts due to existing site constraints.
-
Homeless Shelters, Group Homes, and Similar Social Service Establishments
In sleeping rooms with more than 25 beds that are covered by § 36.406(d) a minimum of five percent (5%) of the beds must have clear floor space compliant with section 806.2.3 of the 2010...
-
Section 9, Accessible Transient Lodging (Preamble, Section-by-Section Analysis)
In a facility that is not required to have an elevator, it is not necessary to provide accessible amenities on the inaccessible floors if at least one of each type of amenity is provided...
-
Section 9, Accessible Transient Lodging (Section-By-Section Analysis and Response to Comments)
In a facility that is not required to have an elevator, it is not necessary to provide accessible amenities on the inaccessible floors if at least one of each type of amenity is provided...
- State of California Disability Access Services (DAS) - Boost Your Business: Physical Access, Technical Assistance & CASp
-
Section 4.1.3, Accessible Buildings: New Construction (Preamble, Section-by-Section Analysis)
Sections 4.1.3 (1) through (4) cover accessible routes, protruding objects, ground and floor surfaces, and stairs....
-
Section 4.1.3, Accessible Buildings: New Construction (Section-By-Section Analysis and Response to Comments)
Sections 4.1.3 (1) through (4) cover accessible routes, protruding objects, ground and floor surfaces, and stairs....
-
1016.1 General
The technical requirements address the surface of outdoor recreation access routes, passing spaces, and resting intervals (1016.2); the clear width of outdoor recreation access routes (1016.3...
-
General: ADA Standard Section 306.3.1
Section 306.3.1 of the ADA Standards covers information in the current ADA Standards for knee clearance.
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
1009.5.1 Transfer Platform
Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width. ...
-
Where do I measure for a handrail extension?
regardless, the technical question pertains to where on the handrail you should measure as it turns horizontally toward a wall return, or as it turns downward to a guard/post or down to the floor...
-
General: ADA Standard Section 204.1
Section 204.1 of the ADA Standards covers information on scoping requirements for protruding objects in the most current ADA Standards.
-
A. Fire Alarms
If the building has an audible fire alarm system, do each of the following rooms in the hotel have a visual alarm strobe light mounted on the wall at 80" above the floor to alert deaf persons...
-
Raised Courtroom Stations Not for Members of the Public
One commenter suggested that a sufficient number of accessible benches for judges with disabilities, in addition to requiring accessible witness stands and attorney areas, be required....
-
11B-604.5.2 Rear wall
valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall be permitted to be split or shifted to the open side of the toilet area...
-
1.0 Background
The analysis was limited to wheeled mobility device dimensions, minimum clear floor areas, space requirements for maneuvering, knee and toe clearances and reach limits....