Sloped entries shall comply with Chapter 4 except as modified in 1109.3.1 through 1109.3.3 EXCEPTION: Where sloped entries are provided, the surfaces shall not be required to be slip...
Search Results "Shall"
-
1009.3.1 Sloped Entries
-
703.5 Visual Characters
Visual characters shall comply with 703.5....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
405.1 General
Ramps on accessible routes shall comply with 405....
-
4.5.1* General
Ground and floor surfaces along accessible routes and in accessible rooms and spaces including floors, walks, ramps, stairs, and curb ramps, shall be stable, firm, slip-resistant, and shall...
-
7.4.3.2 Cross Slope
The cross slope shall not exceed 1:20 (5 percent). Where the surface is paved or is elevated above the natural ground, the cross slope shall not be steeper than 1:48 (2 percent). ...
-
402.2.2 Braille Instructions
Where speech output is required by 402.2, braille instructions for initiating the speech mode of operation shall be provided....
-
4.16.3* Height
The height of water closets shall be 17 in to 19 in (430 mm to 485 mm), measured to the top of the toilet seat (see Fig. 29(b))....
-
4.5.1* GENERAL
Ground and floor surfaces along accessible routes and in accessible rooms and spaces, including floors, walks, ramps, stairs, and curb ramps, shall be stable, firm, slip-resistant, and shall...
-
4.16.3* HEIGHT
The height of water closets shall be 17 in to 19 in (430 mm to 485 mm), measured to the top of the toilet seat (see Fig. 29(b))....
-
4.5.2 Clear Floor or Ground Space
A clear floor or ground space shall be provided for each trash, recycling, and other essential container....
-
4.25.3 HEIGHT
Accessible storage spaces shall be within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
-
2.4 Slope
The running slope (grade) and cross slope of ORARs shall comply with section 2.4. ...
-
11B-1009.3.1 Sloped entries
Sloped entries shall comply with Division 4 except as modified in Sections 11B-1009.3.1 through 11B-1009.3.3....
-
11B-203.12 Animal containment areas
Animal containment areas that are not for public use shall not be required to comply with these requirements or to be on an accessible route....
-
11B-1008.4.1 Turning space
At least one turning space complying with Section 11B-304 shall be provided on the same level as play components....
-
§ 37.49(d)(1)
(1) Half the responsibility for the station shall be assumed by the owner(s) of the station....
-
11B-306.2.1 General
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...
-
11B-705.1.2.1 Platform edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform....
-
11B-206.2.17 Play areas
Play areas shall provide accessible routes in accordance with Section 11B-206.2.17....
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
§ 37.143(a)
(a) Each entity shall begin implementation of its complementary paratransit plan, pending notice from FTA....
-
11B-1008.3.2 Transfer steps
Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required to be on accessible routes....
-
11B-604.8.2.3 Grab bars
Grab bars shall comply with Section 11B-609. A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....