Parking spaces complying with Section 11B-502 shall be identified by signs complying with Sections 11B-502.6 and 11B-502.8. Exceptions: 1. Reserved. [2010 ADAS] 1. ...
Search Results "Shall"
Commonly Searched Documents
-
11B-216.5.1 Parking spaces
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches...
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
-
11B-223.2.1 Facilities not specializing in treating conditions that affect mobility
conditions that affect mobility, including hospitals, psychiatric and detoxification facilities, at least 10 percent, but no fewer than one, of the patient bedrooms or resident sleeping rooms shall...
-
11B-233.3.1.2 Residential dwelling units with adaptable features
In facilities with residential dwelling units, adaptable residential dwelling units complying with Sections 11B-809.6 through 11B-809.12. shall be provided as required by Sections 11B-233.3.1.2.1...
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
11B-206.2.15 Golf facilities
At least one accessible route shall connect accessible elements and spaces within the boundary of the golf course....
-
11B-215.5 Residential facilities
Where provided in residential dwelling units required to comply with Section 11B-809.5, fire alarms shall comply with Chapter 9, Section 907.5.2.3.3 and carbon monoxide alarms shall comply...
-
11B-502.3 Access aisle
Access aisles serving parking spaces shall comply with Section 11B-502.3. Access aisles shall adjoin an accessible route....
-
11B-216.5.1 Parking spaces
Parking spaces complying with Section 11B-502 shall be identified by signs complying with Sections 11B-502.6 and 11B-502.8. Exceptions: 1. Reserved. [2010 ADA Standards] 1....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
11B-809.8 Doors
Doors to small mechanical closets specifically dedicated to furnaces or hot water heaters shall not be required to comply with this section....
-
Recessed Doors and Gates: ADA Standard Section 404.2.4.3
Section 404.2.4.3 covers the current ADA Standards for maneuvering clearances at recessed doors and gates.
-
General: ADA Standard Section 707.1
Automatic teller machines and fare machines shall comply with 707. Advisory 707.1 General....
-
Sloped Entries: ADA Standard Section 1009.3
Sloped entries shall comply with 1009.3. Advisory 1009.3 Sloped Entries. Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
1.1.8.2 Locally adopted energy standards - California Energy Code, Part 6.
In addition to the provisions of Section 1.1.8.1 of this part, the provisions of this section shall apply to a city, county, and cities and counties adopting local energy standards applicable...
-
11B-201.3 Temporary and permanent structures
These requirements shall apply to temporary and permanent buildings and facilities. Advisory 11B-201.3 Temporary and permanent structures....
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3....
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
1.2.3 Alternative materials, design and methods of construction and equipment
An alternative material, design or method of construction shall be approved where the building official finds that the proposed design is satisfactory and complies with the intent of the...
-
11B-706.3 Receiver hearing-aid compatibility
Receivers required to be hearing-aid compatible shall interface with telecoils in hearing aids through the provision of neckloops....
-
1607A.9.2 Grab bars, shower seats and accessible benches
Grab bars, shower seats and accessible benches shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar, shower...
-
§ 382.40a Boarding assistance for large aircraft
(b) Carriers shall, in cooperation with the airports they serve, provide boarding assistance to individuals with disabilities using mechanical lifts, ramps, or other suitable devices that...